Tozzi P, Corno A F, Marty B, von Segesser L K
Department of Cardio-Vascular Surgery, Centre Hospitalier Universitaire Vaudois (CHUV), Rue du Bugnon, 46, 1011 Lausanne, Switzerland.
Eur J Vasc Endovasc Surg. 2004 May;27(5):498-500. doi: 10.1016/j.ejvs.2004.02.004.
We designed an animal study to determine the feasibility of videoendoscopic thoracic aorta to iliac artery bypass using a sutureless anastomotic device for proximal anastomosis construction.
In 12 pigs the descending thoracic aorta was exposed using the thoracoscopic technique. A 4 mm PTFE thin wall graft was used as conduit. The proximal anastomosis was constructed using a mechanical device for sutureless anastomosis inserted through the camera port incision. The prosthesis was passed through the diaphragm in the retroperitoneal space and the distal anastomosis was done with running suture.
The operation was successfully completed in 11 animals. One animal died due to hemorrage during anastomosis construction. Mean graft flow was 144 ml/min (range 88-167 mmHg). The angiogram showed no graft kinking or stenosis. Total operative time was 58 min (range 47-68 min).
This approach allows quick and excellent exposure of the entire descending thoracic aorta. The use of the sutureless device to perform the proximal anastomosis dramatically reduces the technical demands of this procedure and could avoid an aortic clamp.
我们设计了一项动物研究,以确定使用无缝合吻合装置构建近端吻合口的视频内镜下胸主动脉至髂动脉旁路移植术的可行性。
在12头猪中,采用胸腔镜技术暴露降主动脉。使用4毫米聚四氟乙烯薄壁移植物作为管道。通过摄像机端口切口插入用于无缝合吻合的机械装置构建近端吻合口。假体经腹膜后间隙穿过膈肌,远端吻合采用连续缝合完成。
11只动物手术成功完成。1只动物在吻合口构建过程中因出血死亡。平均移植物血流量为144毫升/分钟(范围88 - 167毫米汞柱)。血管造影显示移植物无扭结或狭窄。总手术时间为58分钟(范围47 - 68分钟)。
这种方法能够快速且良好地暴露整个降主动脉。使用无缝合装置进行近端吻合显著降低了该手术的技术要求,并可避免使用主动脉夹。