Abstract

Animal studies are often required to evaluate new cardiovascular medical devices before they reach the market. Moreover, first-generation novel devices including aortic endovascular prostheses and circulatory support devices are often larger than later iterations or tested in a limited range of sizes. One of the challenges in evaluating these devices is finding a model that is both accessible and anatomically similar to humans, as there is a paucity of data on vascular dimensions in large animals. We set out to complete a comprehensive review of available reports on vascular dimensions in swine, ovine, and bovine models, with a particular focus on the descending aorta and ilio-femoral arteries. We searched Embase and MEDLINE databases for reports of descending aorta and peripheral vascular dimension in large animal models. Data from swine, ovine, and bovine models were separated by weight into 3 categories: 40 to 60 kg, 61 to 80 kg, and >80 kg. We also incorporate our computed tomography angiography data from 4 large sheep and 9 calves into this review. Swine, sheep, and calf >80 kg may serve as the best models to maximize aortic diameter resemblance to humans. If device implantation can be achieved in aortas of smaller dimensions, care should be taken to ensure access site suitability such as the common femoral artery in these smaller animals.

摘要

动物研究通常是在新的心血管医疗器械进入市场之前进行的,以评估其安全性和有效性。此外,包括主动脉血管内假体和循环支持设备在内的第一代新型设备通常比后续迭代产品更大,或者仅在有限的尺寸范围内进行测试。评估这些设备的一个挑战是找到一种既易于接近又与人体解剖结构相似的模型,因为在大型动物中,血管尺寸的数据很少。我们着手对猪、羊和牛模型中血管尺寸的现有报告进行全面回顾,特别关注降主动脉和髂股动脉。我们在 Embase 和 MEDLINE 数据库中搜索了关于大型动物模型降主动脉和外周血管尺寸的报告。根据体重,猪、羊和牛模型的数据分为 3 类:40-60kg、61-80kg 和>80kg。我们还将我们从 4 只大绵羊和 9 只小牛中获得的计算机断层血管造影数据纳入了本综述。>80kg 的猪、绵羊和小牛可能是最大限度地模拟人类主动脉直径的最佳模型。如果可以在较小尺寸的主动脉中植入设备,则应注意确保进入部位的适用性,例如这些较小动物的股总动脉。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2d68/10159216/69d64ed12e3b/10.1177_15569845231164134-img1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验