Joseph T, Adeosun A, Paes T, Bahal V
Kettering General Hospital, Rothwell Road, Kettering NN16 8UZ, UK.
Eur J Vasc Endovasc Surg. 2004 May;27(5):549-52. doi: 10.1016/j.ejvs.2004.01.018.
Suture-hole bleeding is a considerable problem in vascular procedures using polytetrafluoroethylene (PTFE) grafts. This study aimed to study the efficacy of TachoComb H patches in controlling suture-hole bleeding.
Prospective randomised controlled trial. Materials and methods. Patients undergoing femoral anastomosis and femoral or carotid patch angioplasty with PTFE grafts were prospectively randomised to TachoComb H patches or standard compression with surgical swabs.
Twenty four patients were randomised (12 patients in each treatment group). The median time to haemostasis was 300 (range 180-600)s in patients treated with TachoComb H and 660 (range 180-1200)s in the control group. The log rank test of equality over treatments based on the 22 patients with assessment of time to haemostasis showed statistical significance (p=0.0134). There were no serious complications associated with use of TachoComb H patches.
TachoComb H patches were found to be safe and effective for the control of suture-hole bleeding in patients undergoing vascular reconstruction with PTFE grafts.
在使用聚四氟乙烯(PTFE)移植物的血管手术中,缝合孔出血是一个相当严重的问题。本研究旨在探讨速即纱H贴片控制缝合孔出血的疗效。
前瞻性随机对照试验。材料与方法。接受PTFE移植物股动脉吻合术及股动脉或颈动脉补片血管成形术的患者被前瞻性随机分为速即纱H贴片组或用手术拭子进行标准压迫组。
24例患者被随机分组(每个治疗组12例患者)。使用速即纱H治疗的患者止血的中位时间为300(范围180 - 600)秒,对照组为660(范围180 - 1200)秒。基于22例有止血时间评估的患者进行的治疗间相等性对数秩检验显示有统计学意义(p = 0.0134)。使用速即纱H贴片未出现严重并发症。
发现速即纱H贴片对于接受PTFE移植物血管重建的患者控制缝合孔出血安全有效。