Suppr超能文献

股下聚四氟乙烯旁路移植术中远端吻合口置入静脉袖套的随机临床试验

Randomized clinical trial of distal anastomotic interposition vein cuff in infrainguinal polytetrafluoroethylene bypass grafting.

作者信息

Griffiths G D, Nagy J, Black D, Stonebridge P A

机构信息

Department of Vascular Surgery, Ninewells Hospital, Dundee DD1 9SY, UK.

出版信息

Br J Surg. 2004 May;91(5):560-2. doi: 10.1002/bjs.4501.

Abstract

BACKGROUND

The aim was to examine the effect of a Miller vein cuff at the distal anastomosis on the medium- to long-term patency and limb salvage rates of femoral to above-knee and femoral to below-knee popliteal artery polytetrafluoroethylene (PTFE) bypasses.

METHODS

This study involved extended follow-up of the original cohort of patients included in a previously reported multicentre randomized clinical study. Outcome measures were bypass graft patency and limb salvage.

RESULTS

Two hundred and sixty-one bypass operations were originally randomized. For this study, full data were available on 235 (120 with a Miller cuff, 115 without). The cumulative 5-year patency rate for above-knee bypasses with a Miller cuff was 40 per cent, compared with 42 per cent for non-cuffed bypasses (P = 0.702). The cumulative 3-year patency rate for below-knee bypasses with a Miller cuff was 45 per cent, compared with 19 per cent for non-cuffed bypasses (P = 0.018). A Miller cuff had no significant effect on limb salvage for above-knee or below-knee bypasses.

CONCLUSION

Three-year patency rates of femoral to below-knee popliteal PTFE bypasses were improved by a Miller cuff. Miller cuffs had no effect on patency rates for femoral to above-knee popliteal bypasses at 5 years and did not improve limb salvage in either group.

摘要

背景

目的是研究在远端吻合口处使用米勒静脉袖套对股动脉至膝上及股动脉至膝下腘动脉聚四氟乙烯(PTFE)旁路移植术的中长期通畅率和肢体挽救率的影响。

方法

本研究对先前报道的一项多中心随机临床研究中的原始患者队列进行了长期随访。观察指标为旁路移植血管的通畅率和肢体挽救情况。

结果

最初有261例旁路手术被随机分组。在本研究中,235例患者有完整数据(120例使用米勒袖套,115例未使用)。使用米勒袖套的膝上旁路移植术的5年累积通畅率为40%,未使用袖套的为42%(P = 0.702)。使用米勒袖套的膝下旁路移植术的3年累积通畅率为45%,未使用袖套的为19%(P = 0.018)。米勒袖套对膝上或膝下旁路移植术的肢体挽救情况无显著影响。

结论

米勒袖套可提高股动脉至膝下腘动脉PTFE旁路移植术的3年通畅率。米勒袖套对股动脉至膝上腘动脉旁路移植术的5年通畅率无影响,且两组的肢体挽救情况均未改善。