Cohen H L, Shapiro M L, Haller J O, Glassberg K
Department of Radiology, North Shore University Hospital-Cornell University Medical College, Manhasset, NY.
Pediatr Radiol. 1992;22(4):296-7. doi: 10.1007/BF02019865.
Four cases of intrascrotal hematoma simulating testicular rupture were noted in teenagers. Careful sonographic technique allowed for the discovery of the normal testicle in a more peripheral location in the scrotum. Duplex doppler aided in confirming a normal testis in one case.
在青少年中发现了4例模拟睾丸破裂的阴囊内血肿。仔细的超声检查技术能够发现正常睾丸位于阴囊更外周的位置。在1例病例中,双功能多普勒有助于确认睾丸正常。