A method for determination of the climate gases CH4, CO2 and N2O in air samples and soil atmosphere was developed using GC-MS. The method uses straightforward gas chromatography (separation of the gases) with a mass spectrometric detector in single ion mode (specific determination). The gases were determined with high sensitivity and high sample throughput (18 samples h(-1)). The LOD (3sigma) for the gases were 0.10 micro L L(-1) for CH4, 20 microL L(-1) for CO2 and 0.02 microL L(-1) for N2O. The linear range (R2 = 0.999) was up to 500 microL L(-1) for CH4, 4000 microL L(-1) for CO2 and 80 microL L(-1) for N2O. The samples were collected in 10 mL vials and a 5 microL aliquot was injected on column. The method was tested against certified gas references, the analytical data gave an accuracy within +/-5% and a precision of +/-3%. The presence of < or = 10% by volume of C2H2 (often used experimentally to prevent N2 formation from N2O) did not interfere with detection for the targeted trace gases.

摘要

开发了一种使用气相色谱 - 质谱联用仪(GC - MS)测定空气样本和土壤大气中气候气体CH4、CO2和N2O的方法。该方法采用直接气相色谱法(气体分离),并配备单离子模式的质谱检测器(特异性测定)。这些气体的测定具有高灵敏度和高样品通量(每小时18个样品)。CH4、CO2和N2O的检测限(3σ)分别为0.10微升/升、20微升/升和0.02微升/升。CH4的线性范围(R2 = 0.999)高达500微升/升,CO2为4000微升/升,N2O为80微升/升。样品收集在10毫升小瓶中,取5微升等分试样注入色谱柱。该方法针对有证气体标准物质进行了测试,分析数据的准确度在±5%以内,精密度为±3%。体积分数≤10%的C2H2(常用于实验中防止N2O生成N2)的存在不干扰目标痕量气体的检测。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验