Bentourkia M'hamed, Noel Pierre-Denis
Department of Nuclear Medicine and Radiobiology, 3001, 12th Avenue North, University of Sherbrooke, Sherbrooke, Québec J1H 5N4, Canada.
Comput Med Imaging Graph. 2004 Jul;28(5):279-87. doi: 10.1016/j.compmedimag.2004.04.001.
Quantitative analysis in positron emission tomography imaging usually necessitates several studies carried out under the same protocol in order to get functional or metabolic parameter values with low variations. Apart from subject preparation and measurements in similar conditions, the data analysis should be done as uniformly as possible. In this work we report PET data obtained in normal and ischemic rats, measured with (13)N-ammonia and (11)C-acetate to extract myocardial blood flow and oxygen consumption, and analysed with the usual region of interest (ROI) drawing method in each rat individually, in comparison to a new method based on resampling all the rat heart images to a common model, then the ROIs are drawn once and copied onto each rat image sequence.
正电子发射断层扫描成像中的定量分析通常需要按照相同方案进行多项研究,以便获得变化较小的功能或代谢参数值。除了在相似条件下进行受试者准备和测量外,数据分析也应尽可能统一。在这项工作中,我们报告了在正常大鼠和缺血大鼠中获得的PET数据,这些数据是用(13)N-氨和(11)C-乙酸盐测量的,以提取心肌血流量和氧耗量,并与一种新方法进行比较,该新方法是将所有大鼠心脏图像重采样到一个通用模型,然后绘制一次感兴趣区域(ROI)并将其复制到每个大鼠图像序列上,而传统方法是在每只大鼠个体上单独绘制ROI。