Bayindir Yusuf Ziya, Bayindir Funda, Akyil M Samil
Conservative Dentistry Department, Atatürk University, Erzurum, Turkey.
Dent Mater J. 2004 Jun;23(2):117-20. doi: 10.4012/dmj.23.117.
The purpose of this laboratory investigation was to evaluate the bond strength of permanent cement (Duo-cement Kit, Meron, Durelon) to commonly used core build-up materials (President, Dyract AP, Ionofil, Vitremer). Sixty specimens (five of each product) were fabricated as a canine core build- up. Full crown castings were made to fit each core specimen. Full crown castings were cemented to core samples and stored at 37 degrees C and 100% humidity for 10 days. After storage, the bond strength was measured with a Haunsfield tensometer in tensile mode at a crosshead speed of 5 mm/min. Statistical evaluation was performed with univariate analysis of variance (P<0.001). The cement types affected the bond strength of full crown castings to core materials (F: 14.80; P<0.001). The interaction between the cement and core materials was significant (F: 3.69; P<0.01). According to the Duncan's test it was found that the values of Duo-cement were statistically different from the other cements.
本实验室研究的目的是评估永久性粘结剂(双组分粘结剂套件,Meron,Durelon)与常用的核桩材料(President、Dyract AP、Ionofil、Vitremer)之间的粘结强度。制作了60个标本(每种产品5个)作为犬科动物核桩。制作全冠铸件以适配每个核桩标本。将全冠铸件粘结到核桩样本上,并在37摄氏度和100%湿度下储存10天。储存后,使用亨氏拉力试验机以5毫米/分钟的十字头速度在拉伸模式下测量粘结强度。采用单因素方差分析进行统计学评估(P<0.001)。粘结剂类型影响全冠铸件与核桩材料之间的粘结强度(F:14.80;P<0.001)。粘结剂与核桩材料之间的相互作用显著(F:3.69;P<0.01)。根据邓肯检验发现,双组分粘结剂的值与其他粘结剂在统计学上存在差异。