Is the ARX index a more sensitive indicator of anesthetic depth than the bispectral index during sevoflurane/nitrous oxide anesthesia?

作者信息

Nishiyama T, Matsukawa T, Hanaoka K

机构信息

Department of Anesthesiology, The University of Tokyo, Japan.

出版信息

Acta Anaesthesiol Scand. 2004 Sep;48(8):1028-32. doi: 10.1111/j.0001-5172.2004.00468.x.

Abstract

BACKGROUND

During general anesthesia, hypnotic components have been monitored with electroencephalogram. The bispectral index is derived from a cortical electroencephalogram, but the A-line ARX index is the electroencephalographic response to auditory stimuli. The purpose of this study was to compare the changes of the A-line ARX index and the bispectral index during sevoflurane - nitrous oxide anesthesia.

METHODS

One hundred females aged 30-60 years, and scheduled for partial mastectomy, were divided into two groups. Anesthesia was induced with sevoflurane 5% and nitrous oxide in oxygen for 3 min. A laryngeal mask airway was inserted, and anesthesia was maintained with sevoflurane 1-2% and nitrous oxide in oxygen. During surgery, the sevoflurane end-tidal concentration was kept at 0.5%, 1%, or 2% for 5 min before each measurement. Blood pressure, heart rate, and the A-line ARX index (n = 50), and the bispectral index (n = 50) were measured.

RESULTS

Blood pressure and heart rate increased following laryngeal mask airway insertion and blood pressure decreased at 2% sevoflurane in both groups similarly. The A-line ARX index, but not the bispectral index, increased significantly by laryngeal mask airway insertion and skin incision. The A-line ARX index decreased at 2% sevoflurane compared with 0.5%, while the bispectral index remained unchanged.

CONCLUSION

During sevoflurane-nitrous oxide anesthesia, the A-line ARX index might be a more sensitive indicator of anesthetic depth than the bispectral index.

摘要

背景

在全身麻醉期间,已通过脑电图监测催眠成分。双谱指数源自皮质脑电图,但A线ARX指数是对听觉刺激的脑电图反应。本研究的目的是比较七氟醚-氧化亚氮麻醉期间A线ARX指数和双谱指数的变化。

方法

100名年龄在30至60岁之间、计划行部分乳房切除术的女性被分为两组。用5%七氟醚和氧气中的氧化亚氮诱导麻醉3分钟。插入喉罩气道,并用1%至2%七氟醚和氧气中的氧化亚氮维持麻醉。手术期间,每次测量前将七氟醚呼气末浓度保持在0.5%、1%或2% 5分钟。测量血压、心率、A线ARX指数(n = 50)和双谱指数(n = 50)。

结果

插入喉罩气道后血压和心率升高,两组在七氟醚浓度为2%时血压均有相似程度的下降。插入喉罩气道和皮肤切开后,A线ARX指数显著升高,而双谱指数未升高。与0.5%相比,七氟醚浓度为2%时A线ARX指数下降,而双谱指数保持不变。

结论

在七氟醚-氧化亚氮麻醉期间,A线ARX指数可能比双谱指数更能敏感地反映麻醉深度。