Vassiou K, Vlychou M, Moisidou R, Sioka A, Fezoulidis I V
Department of Radiology, University of Thessalia, Larissa, Greece.
Rofo. 2004 Oct;176(10):1453-7. doi: 10.1055/s-2004-813170.
Prospective evaluation of contrast-enhanced sonography (CES) as an alternative to radiographic voiding cystourethrography (VCUG) in the detection of vesicoureteral reflux (VUR).
Seventy-six children (age range: 0 - 9 years, mean age 1.4 years) with suspicion of VUR due to various indications were examined by contrast-enhanced sonography (CES) and VCUG. CES examination was performed after instillation of Levovist into the catheterized urinary bladder, which had been prefilled with normal saline. Reflux was diagnosed when hyperechogenic microbubbles were observed in the renal units. Thereafter, VCUG was performed in all patients through the same catheter. CES findings were compared to the results of VCUG.
CES showed VUR in 24 renal units whereas VCUG showed reflux in 18 renal units. With regard to the presence of VUR, the findings obtained by both methods were concordant in 17 renal units. Taking VCUG as the reference standard, the sensitivity of CES was 96 %, the specificity was 94.8 %, the positive predictive value 77.4 % and the negative predictive value 99.2 %. Additionally, McNemar test showed that CES detected a statistically significant higher number of renal units with VUR (p < 0.05).
It is suggested that CES is an accurate and reliable imaging modality for the detection of VUR, although it cannot replace VCUG in some cases. In addition, CES can be recommended in the follow-up of VUR, reducing the number of radiographic investigations.
前瞻性评估超声造影(CES)作为排尿性膀胱尿道造影(VCUG)的替代方法用于检测膀胱输尿管反流(VUR)。
对76例因各种指征怀疑有VUR的儿童(年龄范围:0 - 9岁,平均年龄1.4岁)进行超声造影(CES)和VCUG检查。在向预先充满生理盐水的导尿膀胱内注入声诺维后进行CES检查。当在肾单位中观察到高回声微泡时诊断为反流。此后,所有患者通过同一导管进行VCUG检查。将CES检查结果与VCUG结果进行比较。
CES显示24个肾单位存在VUR,而VCUG显示18个肾单位有反流。关于VUR的存在,两种方法获得的结果在17个肾单位中一致。以VCUG作为参考标准,CES的敏感性为96%,特异性为94.8%,阳性预测值为77.4%,阴性预测值为99.2%。此外,McNemar检验显示CES检测到的有VUR的肾单位数量在统计学上显著更高(p < 0.05)。
尽管在某些情况下CES不能替代VCUG,但提示其是检测VUR的一种准确且可靠的成像方式。此外,CES可推荐用于VUR的随访,减少放射学检查的次数。