Nagy Kornél, Pollreisz Ferenc, Takáts Zoltán, Vékey Károly
Institute of Chemistry, Chemical Research Center, Hungarian Academy of Sciences, H-1025 Pusztaszeri út 59-67, Budapest, Hungary.
Rapid Commun Mass Spectrom. 2004;18(20):2473-8. doi: 10.1002/rcm.1648.
Application of high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) for detection of aldehydes in biological samples such as blood, yoghurt, and milk, is reported. Sample preparation is easy, and the presented method is both sensitive and selective. It is based on the widely used dinitrophenylhydrazine derivatization, followed by extraction with n-hexane and a simple reversed-phase HPLC separation. Detection is performed by atmospheric pressure chemical ionization (APCI) in negative ion mode, with detection limits in the low picogram range. Using MS/MS, acetone and propionaldehyde can clearly be distinguished, facilitating propionaldehyde quantitation even in the presence of high acetone levels. Quantitation by direct MS/MS is also feasible, well suited for high-throughput applications, although not as accurate as using HPLC/MS/MS.
据报道,高效液相色谱(HPLC)和串联质谱(MS/MS)可用于检测血液、酸奶和牛奶等生物样品中的醛类。样品制备简单,所提出的方法既灵敏又具选择性。该方法基于广泛使用的2,4-二硝基苯肼衍生化,随后用正己烷萃取并进行简单的反相HPLC分离。通过大气压化学电离(APCI)在负离子模式下进行检测,检测限在低皮克范围内。使用MS/MS,可以清楚地区分丙酮和丙醛,即使在丙酮含量高的情况下也便于丙醛定量。直接通过MS/MS进行定量也是可行的,非常适合高通量应用,尽管不如使用HPLC/MS/MS准确。