Zhong Kai, Ernst Thomas
Medical Department, Brookhaven National Laboratory, Upton, New York, USA.
Magn Reson Med. 2004 Oct;52(4):898-901. doi: 10.1002/mrm.20201.
A new point-resolved spectroscopy (PRESS) sequence was developed that allows localized human proton MR spectra to be acquired at echo times (TEs) of 10 ms or less. The method was implemented on a 4 Tesla Varian research console and a clinical 3 Tesla Siemens Trio scanner. Human brain spectra acquired in vivo from the prefrontal cortex at TE=8 ms showed improved signals from coupled resonances (such as glutamate, glutamine, and myo-inositol) compared to spectra acquired at TE=30 ms. These improvements should result in more accurate quantitation of these metabolites.
开发了一种新的点分辨光谱法(PRESS)序列,该序列能够在10毫秒或更短的回波时间(TE)下采集局部人体质子磁共振波谱。该方法在一台4特斯拉的瓦里安研究控制台和一台临床用3特斯拉西门子Trio扫描仪上得以实现。在回波时间TE = 8毫秒时从活体前额叶皮质采集的人脑波谱显示,与在TE = 30毫秒时采集的波谱相比,来自耦合共振(如谷氨酸、谷氨酰胺和肌醇)的信号有所改善。这些改进应能使这些代谢物的定量更加准确。