Comparison of a manual and an automated enzymatic technique for determining blood lactate concentrations.

作者信息

Bishop P A, Smith J F, Kime J C, Mayo J M, Tin Y H

机构信息

Human Performance Laboratory, University of Alabama.

出版信息

Int J Sports Med. 1992 Jan;13(1):36-9. doi: 10.1055/s-2007-1021231.

Abstract

Although analysis of lactate concentrations with a Yellow Springs Instruments (YSI) automated analyzer has become very popular in Sports Medicine, the accuracy and reliability of this technique has not been carefully studied. Additionally, the influence of a common lysing agent Triton X-100 (TX) on blood lactate measurements has not been determined. Blood was collected from each of ten subjects at rest and 2, 6, 10, 14 and 20 minutes following maximal exercise (60 samples). Lactate concentration was measured by the YSI and Boehringer Mannheim (BMM) techniques. Two YSI 23L analyzers were supplied with buffer with TX (YSITX), and two without (YSINON) to permit comparisons of lysed and unlysed whole blood lactate levels over the physiological range. MANOVA analysis revealed a statistical difference (p less than .05) between duplicates only for one machine, and duplicates of that machine differed by less than 3%. Mean measurements between similarly prepared machines differed significantly for the NONTX machines, but only by less than 3%. Differences were significant between BMM and YSINON, but not between BMM and YSITX. Regression analysis indicated close agreement between BMM and YSITX (R2 = .99). There was a tendency for a large discrepancy between methods at resting concentrations.

摘要

相似文献

2
Influence of blood handling techniques on lactic acid concentrations.
Int J Sports Med. 1992 Jan;13(1):56-9. doi: 10.1055/s-2007-1021235.
4
Effect of storage on measured blood lactate concentration. A research note.
Int J Sports Med. 1995 Feb;16(2):88-90. doi: 10.1055/s-2007-972970.
5
Semi-automatic blood lactate assay: experiences from an exercise laboratory.
Int J Sports Med. 1983 Feb;4(1):52-5. doi: 10.1055/s-2008-1026016.
7
Evaluation of the Accusport lactate analyser.
Int J Sports Med. 2001 Oct;22(7):525-30. doi: 10.1055/s-2001-17611.
8
Comparison of the Lactate Pro and Analox GM7 blood lactate analysers.
Int J Sports Med. 2005 Oct;26(8):657-61. doi: 10.1055/s-2004-830337.
9
Blood lactate increase during the force velocity exercise test.
Int J Sports Med. 1991 Feb;12(1):17-20. doi: 10.1055/s-2007-1024648.
10
Lactate concentration in plasma and red blood cells during incremental exercise.
Int J Sports Med. 2000 Oct;21(7):463-8. doi: 10.1055/s-2000-7412.

引用本文的文献

2
The influence of sampling site and assay method on lactate concentration in response to rock climbing.
Eur J Appl Physiol. 2006 Nov;98(4):363-72. doi: 10.1007/s00421-006-0289-3. Epub 2006 Sep 8.
3
Blood lactate measurement in recovery as an adjunct to training. Practical considerations.
Sports Med. 1993 Jul;16(1):5-13. doi: 10.2165/00007256-199316010-00002.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验