Sasaki Kousuke, Miura Hiromasa, Takasugi Shinichiro, Jingushi Seiya, Suenaga Eiji, Iwamoto Yukihide
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, 812-8582, Fukuoka, Japan.
J Orthop Sci. 2004;9(5):440-5. doi: 10.1007/s00776-004-0813-4.
We hypothesized that venous obstruction by deep vein thrombosis (DVT) only slightly augments venous outflow from lower limbs by active ankle movements. If our hypothesis is true, we thought that we could develop a new screening method for DVT using duplex ultrasonography. Subjects were 22 lower limbs of 11 patients who gave informed consent for venography after total hip or knee arthroplasty. Around postoperative 19.0 days (range 15-32 days), we measured the ratios, called flow ratios, of the peak flow signal with active maximum ankle dorsiflexion and that at rest using duplex ultrasonography in the bilateral femoral veins. On the same day, we then performed bilateral venography. Thrombosis was detected in 5 of the 22 lower limbs. The mean flow ratios with and without DVT were 1.18 (range 1.0-1.3) and 3.31 (range 1.8-4.8), respectively. The flow ratios with DVT were significantly lower than those without DVT. Pain or difficulty performing active maximum ankle dorsiflexion was not observed in any of the operated or unoperated lower limbs during the ultrasound examination. In conclusion, ultrasonographic measurement of flow ratios may become a simple screening method for DVT in lower limbs without the pain or difficulty of performing active maximum ankle dorsiflexion.
我们假设,深静脉血栓形成(DVT)导致的静脉阻塞仅通过主动踝关节运动略微增加下肢的静脉流出量。如果我们的假设成立,我们认为可以开发一种使用双功超声检查的DVT新筛查方法。研究对象为11例全髋关节或膝关节置换术后同意接受静脉造影的患者的22条下肢。在术后约19.0天(范围15 - 32天),我们使用双功超声检查测量双侧股静脉中主动最大踝关节背屈时的峰值血流信号与静息时的峰值血流信号之比,即血流比。然后在同一天进行双侧静脉造影。在22条下肢中有5条检测到血栓形成。有DVT和无DVT的平均血流比分别为1.18(范围1.0 - 1.3)和3.31(范围1.8 - 4.8)。有DVT的血流比显著低于无DVT的血流比。在超声检查期间,无论是手术侧还是未手术侧的下肢均未观察到主动最大踝关节背屈时的疼痛或困难。总之,超声测量血流比可能成为一种简单的下肢DVT筛查方法,且不会出现主动最大踝关节背屈时的疼痛或困难。