Wrisley Diane M, Marchetti Gregory F, Kuharsky Diane K, Whitney Susan L
Department of Rehabilitation Science, School of Public Health and Health Professions, University at Buffalo, The State University of New York, Buffalo, NY 14214, USA.
Phys Ther. 2004 Oct;84(10):906-18.
The Functional Gait Assessment (FGA) is a 10-item gait assessment based on the Dynamic Gait Index. The purpose of this study was to evaluate the reliability, internal consistency, and validity of data obtained with the FGA when used with people with vestibular disorders.
Seven physical therapists from various practice settings, 3 physical therapist students, and 6 patients with vestibular disorders volunteered to participate.
All raters were given 10 minutes to review the instructions, the test items, and the grading criteria for the FGA. The 10 raters concurrently rated the performance of the 6 patients on the FGA. Patients completed the FGA twice, with an hour's rest between sessions. Reliability of total FGA scores was assessed using intraclass correlation coefficients (2,1). Internal consistency of the FGA was assessed using the Cronbach alpha and confirmatory factor analysis. Concurrent validity was assessed using the correlation of the FGA scores with balance and gait measurements.
Intraclass correlation coefficients of.86 and.74 were found for interrater and intrarater reliability of the total FGA scores. Internal consistency of the FGA scores was.79. Spearman rank order correlation coefficients of the FGA scores with balance measurements ranged from.11 to.67.
The FGA demonstrates what we believe is acceptable reliability, internal consistency, and concurrent validity with other balance measures used for patients with vestibular disorders.
功能性步态评估(FGA)是一项基于动态步态指数的包含10个项目的步态评估。本研究的目的是评估FGA用于前庭疾病患者时所获数据的可靠性、内部一致性和有效性。
来自不同实践场所的7名物理治疗师、3名物理治疗专业学生以及6名前庭疾病患者自愿参与。
所有评估者有10分钟时间来复习FGA的指导说明、测试项目和评分标准。10名评估者同时对6名患者的FGA表现进行评分。患者完成两次FGA测试,两次测试之间休息1小时。使用组内相关系数(2,1)评估FGA总分的可靠性。使用克朗巴哈α系数和验证性因素分析评估FGA的内部一致性。使用FGA分数与平衡和步态测量结果的相关性评估同时效度。
FGA总分的评估者间和评估者内可靠性的组内相关系数分别为0.86和0.74。FGA分数的内部一致性为0.79。FGA分数与平衡测量结果的斯皮尔曼等级相关系数范围为0.11至0.67。
FGA显示出我们认为与用于前庭疾病患者的其他平衡测量方法相比可接受的可靠性、内部一致性和同时效度。