Quality control standards provide a quantity of microorganisms for routine use in microbiology to demonstrate the efficacy of testing methods and culture media. Standards are normally prepared by diluting a culture of microorganisms to obtain a suspension that contains an estimated number of colony-forming units per milliliter. The variability and inaccuracy of these standards increase the potential for false results. Flow cytometry has been used extensively to prepare precise standards of Cryptosporidium and Giardia that contain exact numbers of organisms in a volume of liquid (1). However, the same levels of accuracy have yet to be obtained for bacterial quality control standards.
A modification of a Becton Dickinson FACScalibur flow cytometer enabled 30 bacterial cells to be sorted into a single droplet, mixed with a cryoprotective solution within the droplet, and frozen in liquid nitrogen. The frozen droplets were then freeze dried for stable preservation of the viable bacterial cells.
A freeze-dried sphere 3 mm in diameter was produced, which contained 30 microorganisms. The within-batch variation for these freeze-dried spheres was no greater than two standard deviations, and the between-batch variation was less than one standard deviation.
Bacterial reference controls can now be produced with consistent accuracy and unparalleled precision, thus enabling harmonization across the microbiological testing industry.
质量控制标准为微生物学常规使用提供一定数量的微生物,以证明检测方法和培养基的有效性。标准通常通过稀释微生物培养物来制备,以获得每毫升含有估计数量菌落形成单位的悬浮液。这些标准的变异性和不准确性增加了得出错误结果的可能性。流式细胞术已被广泛用于制备含有精确数量隐孢子虫和贾第虫的精确标准品,这些标准品在一定体积的液体中含有确切数量的生物体(1)。然而,细菌质量控制标准尚未达到同样的准确度水平。
对贝克曼库尔特FACScalibur流式细胞仪进行改造,使30个细菌细胞能够被分选到单个液滴中,与液滴内的冷冻保护溶液混合,并在液氮中冷冻。然后将冷冻的液滴进行冻干,以稳定保存活细菌细胞。
制备出直径为3毫米的冻干球体,其中含有30个微生物。这些冻干球体的批内变异不大于两个标准差,批间变异小于一个标准差。
现在可以生产出具有一致准确性和无与伦比精度的细菌参考对照品,从而实现微生物检测行业的统一。