Ghersin Eduard, Brook Olga R, Meretik Shimon, Kaftori Joseph K, Ofer Amos, Amendola Marco A, Engel Ahuva
Department of Diagnostic Imaging, Rambam Medical Center, PO Box 9602, Haifa 31096, Israel.
AJR Am J Roentgenol. 2004 Dec;183(6):1691-6. doi: 10.2214/ajr.183.6.01831691.
The purpose of this study was to design an alternative imaging technique to CT urography in patients with high-grade urinary tract obstruction, with or without impaired renal function, that uses the superior resolution of MDCT and avoids IV contrast material administration.
Antegrade MDCT pyelography is an alternative imaging technique to CT urography in patients with high-grade urinary tract obstruction with or without impaired renal function. It enables accurate diagnosis of the level of obstruction, as well as its etiology, including nephroureterolithiasis, urothelial tumors, primary congenital megaureter, uretero-pelvic junction stenosis, ureteral edema, ureteral stricture, retroperitoneal fibrosis, and pelvic lymphadenopathy.