Suppr超能文献

对切牙进行轴向刺激时人体下颌反射的肌电图、力量及放电频率分析

EMG, force and discharge rate analysis of human jaw reflexes in response to axial stimulation of the incisor.

作者信息

Brinkworth Russell S A, Türker Kemal S

机构信息

Research Centre for Human Movement Control, Discipline of Physiology, School of Molecular and Biomedical Science, The University of Adelaide, 5005, Adelaide, South Australia, Australia.

出版信息

Exp Brain Res. 2005 Feb;161(2):145-54. doi: 10.1007/s00221-004-2053-4. Epub 2004 Nov 13.

Abstract

Reflex studies utilising controlled stimulation along the long axis of human incisors are relatively new, and the effects that various stimulus parameters have on the elicited reflexes are not fully understood. Twelve subjects were recruited to determine the effects that contraction level, stimulus force and amount of constant force applied between stimuli have on the reflex response of the masseter muscle. Multi-unit intramuscular electromyogram (EMG) was recorded alongside surface EMG to determine whether any differences existed between the two. Furthermore, cumulative peri-stimulus "dischargegrams" were constructed to determine whether events seen in the EMG corresponded to changes in the discharge rates of the underlying motor units. Axial stimulation of the incisor induced a response in the EMG comprising of peak-trough-peak, with the trough being the most dominant. The bite force record showed only a reduction (relaxation) in response to the stimulation. The most significant experimental factor affecting the reflex occurrence and strength was the stimulus force. Although the latency, duration and occurrence rates were not significantly different, the strength of the responses was greater in intramuscular recordings compared with the surface recordings. Discharge rate analysis showed that approximately two-thirds of the late peaks detected in the EMG did not correspond to an increase in the discharge rates of the underlying units; hence they were due to the clustering of action potentials following the trough and not to a change in the membrane potential of the motoneurone. It was also found that the duration of the trough, as seen by the reduced cumulative discharge rate of the underlying units, was longer than indicated by the EMG.

摘要

利用沿人类切牙长轴进行的受控刺激的反射研究相对较新,各种刺激参数对诱发反射的影响尚未完全了解。招募了12名受试者,以确定收缩水平、刺激力以及刺激之间施加的恒力大小对咬肌反射反应的影响。同时记录多单位肌内肌电图(EMG)和表面肌电图,以确定两者之间是否存在差异。此外,构建累积刺激周围“放电图”,以确定肌电图中观察到的事件是否与基础运动单位放电率的变化相对应。切牙的轴向刺激在肌电图中诱发了一个峰-谷-峰反应,其中谷最为明显。咬力记录显示仅对刺激有降低(放松)反应。影响反射发生和强度的最显著实验因素是刺激力。尽管潜伏期、持续时间和发生率没有显著差异,但与表面记录相比,肌内记录中的反应强度更大。放电率分析表明,在肌电图中检测到的晚期峰值中,约三分之二与基础单位放电率的增加不对应;因此,它们是由于谷后动作电位的聚集,而不是运动神经元膜电位的变化。还发现,从基础单位累积放电率降低来看,谷的持续时间比肌电图显示的更长。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验