Matsopoulos George K, Asvestas Pantelis A, Mouravliansky Nikolaos A, Delibasis Konstantinos K
IEEE Trans Med Imaging. 2004 Dec;23(12):1557-63. doi: 10.1109/TMI.2004.836547.
In this paper, an automatic method for registering multimodal retinal images is presented. The method consists of three steps: the vessel centerline detection and extraction of bifurcation points only in the reference image, the automatic correspondence of bifurcation points in the two images using a novel implementation of the self organizing maps and the extraction of the parameters of the affine transform using the previously obtained correspondences. The proposed registration algorithm was tested on 24 multimodal retinal pairs and the obtained results show an advantageous performance in terms of accuracy with respect to the manual registration.
本文提出了一种用于配准多模态视网膜图像的自动方法。该方法包括三个步骤:仅在参考图像中进行血管中心线检测和分叉点提取,使用自组织映射的一种新颖实现方式自动匹配两幅图像中的分叉点,以及利用先前获得的对应关系提取仿射变换参数。所提出的配准算法在24对多模态视网膜图像上进行了测试,所得结果表明,相对于手动配准,该算法在准确性方面具有优势。