Vita Marina, Skansen Patrik, Hassan Moustapha, Abdel-Rehim Mohamed
Department of Medicine, Division of Hematology, Laboratory of Hematology, Karolinska University Hospital, Huddinge, 141 86 Stockholm, Sweden.
J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Mar 25;817(2):303-7. doi: 10.1016/j.jchromb.2004.12.022.
Roscovitine, a purine analogue that selectively inhibits cyclin-dependent kinases, has been considered as a potential anti-tumor drug. The determination of roscovitine in plasma and urine was performed using microextraction in packed syringe as on-line sample preparation method with liquid chromatography and tandem mass spectrometry. The sampling sorbent utilized was polystyrene polymer. 2H3-lidocaine was used as internal standard. The limit of detection for roscovitine was as low as 0.5 ng/mL and the lower limit of quantification was 1.0 ng/mL. The accuracy and precision values of quality control samples were between +/-15% and < or =11%, respectively. The calibration curve was obtained within the concentration range 0.5-2000 ng/mL in both plasma and urine. The regression correlation coefficients for plasma and urine samples were > or =0.999 for all runs. The present method is miniaturized and fully automated and can be used for pharmacokinetic and pharmacodynamic studies.