Wang Han, Ciobanu Luisa, Webb Andrew
Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
J Magn Reson. 2005 Mar;173(1):134-9. doi: 10.1016/j.jmr.2004.11.024.
A new hardware-based approach is presented to reduce data acquisition times in multi-dimensional NMR spectroscopy using a multiple-coil probe. Using a four-coil setup, two-dimensional COSY and TOCSY spectra were acquired in one-quarter the time of conventional spectra by simultaneous acquisition of different effective t1 evolution times for each coil. Data processing consists of simple phase-shifting and intensity normalization of the individual data sets, and results in spectra almost identical to those acquired in a conventional manner. This method can potentially be integrated with other new data acquisition and processing schemes for further increases in data acquisition speed.