Shi Jie, Gong Xue-yun, Zhu Yong-qin
Department of Chemistry, Zhengzhou University, Zhengzhou 450052, China.
Guang Pu Xue Yu Guang Pu Fen Xi. 2004 Nov;24(11):1451-3.
A hydride generation atomic fluorescence spectrometry method has been developed for the determination of trace lead in traditional Chinese medicines. A high pressure digestion using HNO3-H2O2 system was applied for the pretreatment of traditional Chinese medicine samples and the interval flow precedure was used. The experimental conditions and instrumental operating parameters such as KBH4 concentration, flow rates of carrier and shield gases, current of the lamp and height of the atomizer, have been optimized. Under the optimum conditions the detection limit is 0.08 microg x L(-1). The relative standard deviation is 0.34%. This method is simple, rapid and sensitive, so it can be successfully used for the determination of lead in traditional Chinese medicines.
建立了一种氢化物发生原子荧光光谱法测定中药中的痕量铅。采用HNO3-H2O2体系高压消解对中药样品进行预处理,并采用间歇流动程序。对KBH4浓度、载气和屏蔽气流量、灯电流和原子化器高度等实验条件和仪器操作参数进行了优化。在最佳条件下,检测限为0.08μg·L-1,相对标准偏差为0.34%。该方法简便、快速、灵敏,可成功用于中药中铅的测定。