Tuberculosis is a leading cause of morbidity and mortality worldwide. Susceptibility testing of the causative agent, Mycobacterium tuberculosis, is critical for control of the disease. This study compared the flow cytometric susceptibility assay with the proportion method and the BACTEC TB-460 system. There was agreement between the flow cytometric and proportion methods for 73 (94%) of 78 isoniazid tests, and complete agreement for 26 ethambutol and rifampicin tests. In contrast, the proportion and BACTEC methods failed to agree for 22%, 15% and 8% of isoniazid, ethambutol and rifampicin tests, respectively. These findings indicated that susceptibility testing by the flow cytometric assay is accurate, with results available within 24 h of initiation of the testing procedure.
结核病是全球发病和死亡的主要原因。对病原体结核分枝杆菌进行药敏试验对于控制该疾病至关重要。本研究将流式细胞仪药敏试验与比例法和BACTEC TB - 460系统进行了比较。在78次异烟肼试验中,流式细胞仪法与比例法有73次(94%)结果一致,在26次乙胺丁醇和利福平试验中结果完全一致。相比之下,比例法和BACTEC法在异烟肼、乙胺丁醇和利福平试验中的不一致率分别为22%、15%和8%。这些结果表明,流式细胞仪药敏试验结果准确,且在检测程序开始后24小时内即可获得结果。