van der Meer P F, Gulliksson H, Aubuchon J P, Prowse C, Richter E, de Wildt-Eggen J
Sanquin Blood Bank North-west Region, 1066 CX Amsterdam, the Netherlands.
Vox Sang. 2005 May;88(4):227-34. doi: 10.1111/j.1423-0410.2005.00621.x.
When platelet concentrates (PCs) are shipped from one centre to another, they may remain unagitated for a considerable period of time. It was therefore our aim to study the effects of interruption of agitation on the in vitro parameters of PCs stored in platelet additive solutions.
In this multicentre study, PCs were prepared either by apheresis or from pooled buffy coats, paired to minimize donor-dependent differences, and aliquoted into 3 units with a 'low concentration' (approximately 1 x 10(9) platelets/ml; groups A, B and C) and 3 units with a 'high concentration' (approximately 2 x 10(9) platelets/ml; groups D, E and F). The final composition of the storage medium was 30% plasma and 70% additive solution in all PCs. Either PASIIIM or Composol was used as the additive solution. Agitation was interrupted for 2 days (between days 3 and 5, groups A and D), or for 4 days (between days 1 and 5, groups B and E), and continuous agitation served as the reference (groups C and F). A number of in vitro parameters were used for testing on days 1, 5 and 7.
On day 7, reference units C and F in PASIIIM had significantly higher pH values than the study units in PASIIIM, but all retained a pH of > 6.5 at 37 degrees C. Hypotonic shock response (HSR) results were significantly lower in the high concentration/4-day interruption group (E) than in the other groups. The low-concentration groups in PASIIIM, with agitation interrupted for either 2 days (group A) or 4 days (group B), did not have HSR values significantly different from the respective references. Study groups A, B, D and E in Composol, a solution lacking phosphate, had a pH of approximately 6.5 on day 7, which was significantly lower than that of the references and of the corresponding units in PASIIIM. The pH values were > 7.0 in reference groups C and F in Composol, not significantly different from those in PASIIIM. HSR values were also significantly lower in the Composol study groups. On the other hand, the reference Composol groups showed results similar to units in PASIIIM.
PCs in PASIIIM additive solution with a platelet concentration of approximately 1 x 10(9)/ml can sustain 4 days without agitation. Phosphate may be of importance in maintaining good in vitro characteristics during interruption of agitation.
当血小板浓缩物(PCs)从一个中心转运至另一个中心时,它们可能会在相当长的一段时间内处于未搅动状态。因此,我们的目的是研究搅动中断对储存在血小板添加剂溶液中的PCs体外参数的影响。
在这项多中心研究中,PCs通过单采或从混合的 Buffy 层制备,进行配对以尽量减少供体依赖性差异,并分装成3个“低浓度”单位(约1×10⁹个血小板/毫升;A、B和C组)和3个“高浓度”单位(约2×10⁹个血小板/毫升;D、E和F组)。所有PCs中储存介质的最终组成为30%血浆和70%添加剂溶液。使用PASIIIM或Composol作为添加剂溶液。搅动中断2天(第3天至第5天之间,A和D组),或中断4天(第1天至第5天之间,B和E组),持续搅动作为对照(C和F组)。在第1天、第5天和第7天使用多个体外参数进行检测。
在第7天,PASIIIM中的对照单位C和F的pH值显著高于PASIIIM中的研究单位,但在37℃时所有单位的pH值均保持>6.5。高浓度/4天中断组(E组)的低渗休克反应(HSR)结果显著低于其他组。PASIIIM中的低浓度组,搅动中断2天(A组)或4天(B组),其HSR值与各自的对照无显著差异。Composol(一种不含磷酸盐的溶液)中的研究组A、B、D和E在第7天的pH值约为6.5,显著低于对照以及PASIIIM中相应单位的pH值。Composol中的对照C和F组的pH值>7.0,与PASIIIM中的无显著差异。Composol研究组的HSR值也显著较低。另一方面,对照Composol组的结果与PASIIIM中的单位相似。
血小板浓度约为1×10⁹/毫升的PASIIIM添加剂溶液中的PCs在不搅动的情况下可维持4天。磷酸盐在搅动中断期间维持良好的体外特性方面可能很重要。