In vitro function of buffy coat-derived platelet concentrates stored for 9 days in CompoSol, PASII or 100% plasma in three different storage bags.

作者信息

Cardigan R, Sutherland J, Garwood M, Bashir S, Turner C, Smith K, Hancock V, Wiltshire M, Pergande C, Williamson L M

机构信息

Components Development Laboratory, NHS Blood and Transplant, Brentwood, UK.

出版信息

Vox Sang. 2008 Feb;94(2):103-12. doi: 10.1111/j.1423-0410.2007.01008.x. Epub 2007 Nov 22.

Abstract

BACKGROUND AND OBJECTIVES

The aim of the study was to compare the in vitro quality of buffy coat-derived platelet concentrates (PC) during extended storage in plasma or additive solution in three different storage bags.

MATERIALS AND METHODS

A pooled and split design was chosen so that identical PCs were produced in either 100% plasma, 70% PASII : 30% plasma or 70% CompoSol : 30% plasma (n = 6 each). This was repeated for three different manufacturers' platelet storage bags (Fresenius, Baxter and Pall). PCs were sampled on days 1, 5, 7 and 9 of storage and tested in vitro using a variety of tests of platelet function. For each bag type, storage in PASII or Composol was compared with plasma (data taken across the entire storage period), and differences occurring with time were analysed for all storage media.

RESULTS

The pH of all PCs was > 6.8 at day 9 of storage. In vitro platelet function, as assessed by markers of platelet activation and metabolism, of PCs stored in CompoSol appeared to be similar to that of PCs stored in plasma over 9 days of storage. In contrast, PCs stored in PASII tended to have significantly higher levels of platelet activation (almost a twofold increase in % platelets positive for CD62P by day 5) and lower hypotonic shock response (approximately 40%, by day 7) compared to either PCs stored in 100% plasma or 70% CompoSol. The magnitude of the differences observed between platelet storage media appeared to be dependent on the type of platelet storage bag with the highest degree of platelet activation and lowest hypotonic shock response values being observed in Fresenius bags in combination with PASII.

CONCLUSIONS

The maintenance of platelet function in vitro during extended storage of PCs in platelet additive solutions is dependent on the combination of type of additive solution and type of platelet storage bag. For all bag types studied, storage in PASII resulted in poorer platelet function in vitro.

摘要

背景与目的

本研究旨在比较在三种不同储存袋中,血小板浓缩物(PC)在血浆或添加剂溶液中延长储存期间的体外质量。

材料与方法

采用混合与分割设计,以便在100%血浆、70% PASII:30%血浆或70% CompoSol:30%血浆中制备相同的PC(每种n = 6)。对三种不同制造商的血小板储存袋(费森尤斯、百特和颇尔)重复此操作。在储存的第1、5、7和9天对PC进行采样,并使用多种血小板功能测试进行体外检测。对于每种袋型,将在PASII或Composol中的储存与血浆储存进行比较(整个储存期的数据),并分析所有储存介质随时间出现的差异。

结果

在储存第9天时,所有PC的pH均> 6.8。通过血小板激活和代谢标志物评估,在CompoSol中储存9天的PC的体外血小板功能似乎与在血浆中储存的PC相似。相比之下,与在100%血浆或70% CompoSol中储存的PC相比,在PASII中储存的PC在第5天时血小板激活水平显著更高(CD62P阳性血小板百分比几乎增加两倍),低渗休克反应更低(第7天时约为40%)。观察到的血小板储存介质之间差异的大小似乎取决于血小板储存袋的类型,在费森尤斯袋与PASII组合中观察到最高程度的血小板激活和最低的低渗休克反应值。

结论

在血小板添加剂溶液中延长储存PC期间,体外血小板功能的维持取决于添加剂溶液类型和血小板储存袋类型的组合。对于所有研究的袋型,在PASII中储存导致体外血小板功能较差。