Suppr超能文献

在平均模拟角膜曲率、中央角膜厚度和后表面高度方面,双眼角膜具有高度对称性。

High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation.

作者信息

Myrowitz Elliott H, Kouzis Anthony C, O'Brien Terrence P

机构信息

Wilmer Eye Institute, The Johns Hopkins School of Medicine, Lutherville, Maryland.

出版信息

Optom Vis Sci. 2005 May;82(5):428-431. doi: 10.1097/01.OPX.0000162666.83092.E4.

Abstract

PURPOSE

The purpose of this study was to assess interocular corneal symmetry in average simulated keratometry, corneal thickness, and posterior corneal elevation.

METHODS

This retrospective analysis included data from scanning slit topography (Orbscan II; Bausch and Lomb, Rochester, NY) on 242 eyes from 121 consecutive patients undergoing standard evaluation for consideration of elective laser vision correction. The symmetry between the right and left eye in average simulated keratometry, minimum central corneal thickness, and posterior corneal elevation was assessed by comparative data analysis.

RESULTS

Simulated keratometry ranged from 39.9 to 48.6 D. The interocular difference in average simulated keratometry was 0.47 D (standard deviation [SD] 0.43). The interocular Pearson correlation coefficient for average simulated keratometry was 0.90 (p < 0.001). The range of minimum corneal thickness was 432 to 628 microm. The interocular Pearson correlation coefficient for minimum central corneal thickness was 0.95 (p < 0.001). Right and left eye minimum corneal thickness differed by an average 8 microm (SD 7). The range of posterior elevation was -4 to 54 microm. The average difference in posterior corneal elevation between the right and left eye was 6 microm (SD 5). The interocular Pearson correlation coefficient for posterior corneal elevation was 0.72 (p < 0.001). The average posterior elevation was 19 microm (SD 11).

CONCLUSIONS

Although a wide range of values exists in simulated keratometry, minimum corneal thickness, and posterior corneal elevation, interocular symmetry in all these parameters was very high in this group of consecutive patients. Asymmetry of these interocular parameters may warrant repeat clinical testing for accuracy and may predict corneal abnormalities. Normative data on posterior cornea elevation is presented. This study points out potentially clinically important high interocular corneal symmetry data in simulated keratometry, corneal thickness, and posterior corneal elevation.

摘要

目的

本研究旨在评估平均模拟角膜曲率、角膜厚度和角膜后表面高度的双眼角膜对称性。

方法

这项回顾性分析纳入了连续121例接受选择性激光视力矫正标准评估的患者的242只眼的扫描裂隙地形图(Orbscan II;博士伦公司,纽约州罗切斯特)数据。通过比较数据分析评估双眼在平均模拟角膜曲率、中央角膜最小厚度和角膜后表面高度方面的对称性。

结果

模拟角膜曲率范围为39.9至48.6 D。平均模拟角膜曲率的双眼差异为0.47 D(标准差[SD] 0.43)。平均模拟角膜曲率的双眼Pearson相关系数为0.90(p < 0.001)。中央角膜最小厚度范围为432至628微米。中央角膜最小厚度的双眼Pearson相关系数为0.95(p < 0.001)。双眼中央角膜最小厚度平均相差8微米(SD 7)。后表面高度范围为 -4至54微米。双眼角膜后表面高度的平均差异为6微米(SD 5)。角膜后表面高度的双眼Pearson相关系数为0.72(p < 0.001)。平均后表面高度为19微米(SD 11)。

结论

尽管在模拟角膜曲率、角膜最小厚度和角膜后表面高度方面存在广泛的值范围,但在这组连续患者中,所有这些参数的双眼对称性都非常高。这些双眼参数的不对称可能需要重复进行临床测试以确保准确性,并且可能预测角膜异常。给出了角膜后表面高度的规范数据。本研究指出了在模拟角膜曲率、角膜厚度和角膜后表面高度方面潜在具有临床重要性的高双眼角膜对称性数据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验