Suppr超能文献

有无修整情况下超声倒充填根管末端充填物微渗漏的研究:定量分析

An investigation of microleakage from root-end fillings in ultrasonic retrograde cavities with or without finishing: a quantitative analysis.

作者信息

Gondim Eudes, Kim Syngcuk, de Souza-Filho Francisco José

机构信息

Endodontic Unit, School of Dentistry of Piracicaba, State University of Campinas-UNICAMP- Piracicaba-SP, Brazil.

出版信息

Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005 Jun;99(6):755-60. doi: 10.1016/j.tripleo.2004.08.019.

Abstract

OBJECTIVE

The aim of this study was to make a quantitative assessment of the sealing ability of Super-EBA, IRM, and Pro Root MTA root-end fillings subjected to 3 different finishing techniques.

STUDY DESIGN

Eighty-one ultrasonically prepared root-end cavities in human canines were separated randomly into 3 test groups of 27 roots each. The cavities were filled with Super-EBA, IRM, or Pro Root MTA and finished by ball burnishing. Sequentially, 18 roots from each group received a final smoothing with either a 30-fluted tungsten carbide finishing bur or a Zekrya carbide 28-mm bur. Samples were prepared and immersed in 2% methylene blue dye neutral solution for 12 hours. Roots were ground into a powder and prepared for analysis in an absorbency spectrophotometer.

RESULTS

The results revealed that Pro Root MTA displayed significantly less mean dye microleakage ( P < .05) than Super-EBA and IRM root-end fillings. The Super-EBA root-end fillings, although presenting a greater mean dye microleakage, did not differ significantly from IRM ( P > .05). The finishing technique did not significantly ( P > .05) affect the incidence of microleakage among the materials tested.

CONCLUSIONS

The favorable results obtained with MTA in leakage studies may be related to its good marginal adaptation. Spectrophotometric analysis may provide valuable information about the sealing capacity of root-end fillings. None of the procedures tested were able to avoid leakage, a finding that stresses the importance of the eradication of irritants within the root canal system.

摘要

目的

本研究旨在对采用3种不同修整技术的Super-EBA、IRM和Pro Root MTA根尖充填材料的封闭能力进行定量评估。

研究设计

将81颗经超声预备的人犬根尖洞随机分为3个试验组,每组27颗牙根。用Super-EBA、IRM或Pro Root MTA充填这些洞,并通过球磨进行修整。随后,每组18颗牙根分别用30刃碳化钨修整钻或28 mm Zekrya碳化钻进行最终的平滑处理。制备样本并将其浸入2%亚甲蓝染料中性溶液中12小时。将牙根磨成粉末并准备在吸收分光光度计中进行分析。

结果

结果显示,Pro Root MTA的平均染料微渗漏显著低于Super-EBA和IRM根尖充填材料(P <.05)。Super-EBA根尖充填材料虽然平均染料微渗漏较大,但与IRM相比差异不显著(P >.05)。修整技术对所测试材料的微渗漏发生率没有显著影响(P >.05)。

结论

MTA在渗漏研究中获得的良好结果可能与其良好的边缘适应性有关。分光光度分析可为根尖充填材料的封闭能力提供有价值的信息。所测试的任何程序都无法避免渗漏,这一发现强调了根除根管系统内刺激物的重要性。