Woo Y Joseph, Atluri Pavan, Grand Todd J, Hsu Vivian M, Cheung Albert
Division of Cardiothoracic Surgery, Department of Surgery, University of Pennsylvania School of Medecine, Philadelphia, PA 19104, USA.
Asian Cardiovasc Thorac Ann. 2005 Jun;13(2):157-60. doi: 10.1177/021849230501300213.
During off-pump coronary artery bypass grafting, hypothermia increases vasoconstriction, myocardial afterload, coagulopathy and postoperative bleeding. Traditional thermoregulatory techniques do not maintain core body temperature intraoperatively. The efficacy of a commercially available, computer-controlled, water-circulating, dorsal surface, active warming system for thermoregulatory control was evaluated. All patients who underwent non-emergency off-pump coronary bypass grafting by a single surgeon in a 1-year period were studied: the thermoregulation device was used in 50 cases and unavailable for use in 19. The patients who underwent active thermoregulation demonstrated significantly improved core body temperatures compared to the controls: lowest intraoperative, 35.8 degrees C +/- 0.1 degrees C vs. 35.0 degrees C +/- 0.2 degrees C; immediately postoperative, 36.5 degrees C +/- 0.1 degrees C vs. 35.6 degrees C +/- 0.2 degrees C; and 1-hour postoperative, 36.6 degrees C +/- 0.1 degrees C vs. 35.9 degrees C +/- 0.2 degrees C. Thermoregulated patients had significantly reduced 24-hour chest tube drainage (764 +/- 38 vs. 1227 +/- 183 mL), packed red blood cell transfusions (1.4 +/- 0.2 vs. 3.3 +/- 0.7 units), time to extubation (6.8 +/- 0.5 vs. 11.4 +/- 2.3 hours), intensive care unit stay (1.3 +/- 0.1 vs. 2.0 +/- 0.3 days), and hospital stay (4.3 +/- 0.1 vs. 5.1 +/- 0.3 days).