Suppr超能文献

无骨水泥型髋臼扩张组件及氧化铝-聚乙烯衬垫在股骨头坏死全髋关节置换术中的应用。

The use of cementless expansion acetabular component and an alumina-polyethylene bearing in total hip arthroplasty for osteonecrosis.

作者信息

Kim Y-G, Kim S-Y, Kim S-J, Park B-C, Kim P-T, Ihn J-C

机构信息

Department of Orthopaedic Surgery, Kyungpook National University School of Medicine, Sam-Duck 2 Ga, 50, Jung-Gu 700-721, Korea.

出版信息

J Bone Joint Surg Br. 2005 Jun;87(6):776-80. doi: 10.1302/0301-620X.87B6.15380.

Abstract

We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129). The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years. Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.

摘要

我们对101例晚期股骨头坏死患者连续进行了114例初次全髋关节置换术,使用非骨水泥型髋臼扩张组件。患者手术时的平均年龄为51岁(36至62岁),平均随访时间为110个月(84至129个月)。术前Harris髋关节评分平均为47分,末次随访时提高到93分。在此期间,有两个髋关节更换了聚乙烯内衬,一个髋臼组件断裂进行了翻修。聚乙烯的平均线性磨损率为0.07mm/年,两个髋关节(1.9%)出现髋臼周围骨溶解。Kaplan-Meier分析表明,髋臼组件在十年时无需翻修的生存率为97.8%(95%置信区间0.956至1.000)。我们的研究表明,使用非骨水泥型髋臼扩张组件和氧化铝-聚乙烯承重表面的全髋关节置换术效果良好。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验