The use of electrical stimulation to monitor epidural needle advancement in a porcine model.

作者信息

Tsui Ban C H, Emery Derek, Uwiera Richard R E, Finucane Brendan

机构信息

Departments of *Anesthesiology and Pain Medicine, †Radiology and Diagnostic Imaging, and ‡Health Sciences Laboratory Animal Services, University of Alberta, Edmonton, Canada.

出版信息

Anesth Analg. 2005 Jun;100(6):1611-1613. doi: 10.1213/01.ANE.0000150600.28332.72.

Abstract

Muscle twitches elicited with electrical stimulation (ES) during epidural insertion may indicate epidural needle location. We examined the potential application of ES at 5 mA as a continuous method of monitoring the response to epidural needle advancement in a porcine model. Five 20-kg pigs were used in this study. A needle with a stimulating current of 5 mA was inserted at 20 separate levels in each pig. The needle was advanced until a muscle twitch was observed without loss-of-resistance (LOR). The needle position was then assessed using LOR. At the end of the experiment, an autopsy was performed to assess the spinal cord for injury. A total of 100 needle insertions were performed in the 5 pigs. The threshold current in the epidural space was 3.6 +/- 0.6 mA. In 59 of the needle insertions, LOR was not obtained at the depth at which a muscle twitch was initially observed. However, after advancing these 59 needles another 1-2 mm, LOR was obtained. In the other 41 insertions, LOR was observed without further advancement of the needle. Autopsies indicated there were no dural punctures or spinal cord damage in any of the pigs. These observations suggest that ES can be used to signal that the epidural needle is in or approaching the epidural space. However, the high false positive predictive value (59%) makes it impractical and unreliable to detect the precise entry of a needle into the epidural space in pigs.

摘要

硬膜外穿刺过程中,电刺激(ES)引发的肌肉抽搐可能提示硬膜外针的位置。我们在猪模型中研究了5毫安电刺激作为一种连续监测硬膜外针推进反应的潜在应用。本研究使用了5头20千克重的猪。在每头猪的20个不同节段插入一根带有5毫安刺激电流的针。将针推进直至观察到肌肉抽搐且无阻力消失(LOR)。然后使用LOR评估针的位置。实验结束时,进行尸检以评估脊髓是否受损。5头猪共进行了100次针插入操作。硬膜外间隙的阈值电流为3.6 +/- 0.6毫安。在59次针插入操作中,在最初观察到肌肉抽搐的深度未获得LOR。然而,将这59根针再推进1 - 2毫米后,获得了LOR。在其他41次插入操作中,未进一步推进针就观察到了LOR。尸检表明,所有猪均未出现硬膜穿刺或脊髓损伤。这些观察结果表明,ES可用于提示硬膜外针已进入或正在接近硬膜外间隙。然而,高假阳性预测值(59%)使得在猪中检测针精确进入硬膜外间隙既不实际也不可靠。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验