Suppr超能文献

基于硫堇单层修饰金电极的癌胚抗原免疫分析电化学传感器。

Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode.

作者信息

Dai Zong, Chen Jin, Yan Feng, Ju Huangxian

机构信息

Department of Chemistry, Institute of Chemical Biology, Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210093, China.

出版信息

Cancer Detect Prev. 2005;29(3):233-40. doi: 10.1016/j.cdp.2004.12.003. Epub 2005 Apr 22.

Abstract

A sensor based on thionine monolayer modified gold electrode for determination of carcinoembryonic antigen (CEA) in human serum is proposed. The sensor is prepared by covalently binding thionine to a cysteamine self-assembled monolayer with p-phthaloyl chloride as a linkage, which gives a surface coverage of 8.97+/-3.28 x 10(-12)mol/cm(2) for thionine. The electrochemistry of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 1.47+/-0.84 s(-1). Based on an electrochemical enzyme-linked immunoassay by using the immobilized thionine as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP) labeled anti-CEA antibody, a calibration curve with two linear ranges from 0.6 to 17 and 17 to 200 ng/mL and a detection limit of 0.2 ng/mL for CEA determination is obtained in pH 4.2 PBS containing 2.0 mmol/L H(2)O(2) and 0.5 mol/L NaCl. The sensor shows a good accuracy. The precision and reproducibility are acceptable with the intra-assay CV of 4.9% and 5.9% at 10 and 100 ng/mL CEA concentrations, respectively, and the inter-assays CV of 7.8% at 100 ng/mL CEA. The response of thionine modified electrode shows only 1.6% decrease after 100 replicate measurements and the storage stability is acceptable in a pH 7.0 PBS at 4 degrees C for 1 week. The method avoids the addition of electron transfer mediator to the solution, thus is much simpler. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

摘要

提出了一种基于硫堇单层修饰金电极的传感器,用于测定人血清中的癌胚抗原(CEA)。该传感器通过以对苯二甲酰氯为连接剂,将硫堇共价结合到半胱胺自组装单层上制备而成,硫堇的表面覆盖率为8.97±3.28×10⁻¹²mol/cm²。固定化硫堇的电化学显示出表面控制的电极过程,平均电子转移速率常数为1.47±0.84 s⁻¹。基于电化学酶联免疫分析,使用固定化硫堇作为电极与辣根过氧化物酶(HRP)标记的抗CEA抗体之间的电子转移介质,在含有2.0 mmol/L H₂O₂和0.5 mol/L NaCl的pH 4.2 PBS中,获得了CEA测定的校准曲线,其具有0.6至17和17至200 ng/mL的两个线性范围,检测限为0.2 ng/mL。该传感器具有良好的准确性。在10和100 ng/mL CEA浓度下,批内变异系数分别为4.9%和5.9%,在100 ng/mL CEA时批间变异系数为7.8%,精密度和重现性均可接受。硫堇修饰电极在100次重复测量后响应仅下降1.6%,在4℃的pH 7.0 PBS中储存稳定性在1周内可接受。该方法避免了向溶液中添加电子转移介质,因此更加简单。所提出的方法对于癌症及其转移的诊断和监测具有重要价值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验