[不同采样条件对循环促甲状腺激素和游离甲状腺素测定的影响]

[Effect of various sampling condition on the measurement of circulating TSH and free thyroxine].

作者信息

Nishi I, Okada Y, Hayashi J, Takeoka K, Amino N, Miyai K

机构信息

Central Laboratory for Clinical Investigation, University Hospital, Osaka.

出版信息

Rinsho Byori. 1992 Apr;40(4):417-22.

PMID:1593766
Abstract

We report here the effect of various sampling and storage condition on the measurement of circulating TSH and free thyroxine (FT4). Blood samples were obtained from five normal subjects using four kinds of sampling tubes; plane glass tube, glass tube containing serum separator, and glass tube containing EDTA-2Na or heparin-sodium. We stored whole blood, serum or plasma at low temperature (4-8 degrees C) or at room temperature (20-25 degrees C) from one hour to thirteen days. Both values of EDTA-plasma TSH and FT4 were significantly lower than those of serum samples, EDTA-plasma TSH value was increased gradually during storage at room temperature but not at low temperature. Serum or plasma FT4 values were decreased during storage at room temperature but not at low temperature. In conclusion, circulating TSH and FT4 values are influenced by different sampling tubes and, serum or plasma TSH and FT4 are not always stable under the storage condition at room temperature. Serum samples obtained by using plane glass tube and kept at low temperature give us more reliable values of TSH and FT4.

摘要

我们在此报告各种采样和储存条件对循环促甲状腺激素(TSH)和游离甲状腺素(FT4)测量的影响。使用四种采样管从五名正常受试者采集血样;普通玻璃管、含血清分离器的玻璃管以及含乙二胺四乙酸二钠(EDTA - 2Na)或肝素钠的玻璃管。我们将全血、血清或血浆在低温(4 - 8摄氏度)或室温(20 - 25摄氏度)下储存1小时至13天。EDTA血浆TSH和FT4的值均显著低于血清样本的值,EDTA血浆TSH值在室温储存期间逐渐升高,但在低温下未升高。血清或血浆FT4值在室温储存期间降低,但在低温下未降低。总之,表示循环TSH和FT4的值受不同采样管的影响,并且血清或血浆TSH和FT4在室温储存条件下并不总是稳定的。使用普通玻璃管采集并保存在低温下的血清样本为我们提供了更可靠的TSH和FT4值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验