Three ELISAs for the detection of antibodies against Neospora caninum in bulk milk were evaluated in 162 Dutch dairy herds. The first ELISA was the Dutch Animal Health Service (AHS) in-house ELISA, developed from the routine in-house serum ELISA. The other two ELISAs were commercial milk ELISAs from IDEXX and LSI. Blood samples of all lactating cows in 162 dairy herds were tested using the AHS in-house serum ELISA. Based on previous studies in the Netherlands a within-herd N. caninum seroprevalence of 15% was associated with increased risk for reproductive losses. This percentage was therefore used as positive seroprevalence cut-off value. Repeatability of the ELISAs was evaluated by testing on three different days. The AHS in-house ELISA lacked specificity, probably due to use of a different batch of antigen on the second and third test-day. Cut-off values were determined using misclassification costs term calculations. At cut-off values 0.6 for the IDEXX and 0.2 for the LSI, a herd sensitivity of 61% (95% CI: 49--73%) and 47% (95% CI: 35--60%) was estimated. Herd specificity at these cut-off values was 92% (95% CI: 87--98%) for the IDEXX and 94% (95% CI: 90--99%) for the LSI ELISA. The positive and negative predictive values were 84% (95% CI: 68--100%) and 86% (95% CI: 79--94%) for the IDEXX ELISA, and 85% (95% CI: 67--100%) and 82% (95% CI: 74--90%) for the LSI ELISA. The agreement between all possible combinations of test-days was expressed by kappa values. These were found to be slightly higher for the IDEXX than for the LSI ELISA. It is concluded that both commercial ELISAs performed satisfactorily to detect a within-herd seroprevalence of N. caninum in lactating cows of at least 15%.
在162个荷兰奶牛场中对三种用于检测原料奶中抗犬新孢子虫抗体的酶联免疫吸附测定(ELISA)进行了评估。第一种ELISA是荷兰动物卫生服务局(AHS)的内部ELISA,它是在常规内部血清ELISA的基础上开发的。另外两种ELISA是来自IDEXX和LSI的商用牛奶ELISA。使用AHS内部血清ELISA对162个奶牛场中所有泌乳奶牛的血样进行了检测。根据荷兰此前的研究,牛群内犬新孢子虫血清阳性率达到15%与繁殖损失风险增加相关。因此,该百分比被用作阳性血清阳性率的临界值。通过在三个不同日期进行检测来评估ELISA的重复性。AHS内部ELISA缺乏特异性,可能是因为在第二次和第三次检测日使用了不同批次的抗原。使用错误分类成本项计算来确定临界值。对于IDEXX ELISA,临界值为0.6,对于LSI ELISA,临界值为0.2,估计牛群敏感性分别为61%(95%置信区间:49 - 73%)和47%(95%置信区间:35 - 60%)。在这些临界值下,IDEXX ELISA的牛群特异性为92%(95%置信区间:87 - 98%),LSI ELISA的牛群特异性为94%(95%置信区间:90 - 99%)。IDEXX ELISA的阳性预测值和阴性预测值分别为84%(95%置信区间:68 - 100%)和86%(95%置信区间:79 - 94%),LSI ELISA的阳性预测值和阴性预测值分别为85%(95%置信区间:67 - 100%)和82%(95%置信区间:74 - 90%)。检测日所有可能组合之间的一致性用kappa值表示。发现IDEXX ELISA的kappa值略高于LSI ELISA。结论是,两种商用ELISA在检测泌乳奶牛中犬新孢子虫牛群内血清阳性率至少为15%时表现令人满意。