六种常用听诊器声学特性的比较。

Comparison of the acoustic properties of six popular stethoscopes.

作者信息

Abella M, Formolo J, Penney D G

机构信息

Department of Internal Medicine, St. John Hospital, Detroit, Michigan 48236.

出版信息

J Acoust Soc Am. 1992 Apr;91(4 Pt 1):2224-8. doi: 10.1121/1.403655.

Abstract

This study evaluated stethoscope acoustics by using a sound frequency generator and an active artificial ear. Six popular, currently available stethoscopes were compared in their various modes involving bells, diaphragms, etc.: Littmann Classic II, Littmann Cardiology II, Littmann Master Cardiology, Hewlett-Packard Rappaport-Sprague, Tycos Harvey Triple Head, and Allen Medical Series 5A RPS Binaural. The transfer function was measured from 37.5-1000 Hz, the range where nearly all heart and lung sounds are found. Sound in the low-frequency range (37.5-112.5 Hz) was in most cases amplified by the bells and attenuated by the diaphragms; however, there were no significant differences. Both bells and diaphragms attenuated sound transmission in the high range, and this increased with frequency. The Tycos Harvey Triple Head ribbed diaphragm attenuated sound transmission to a significantly greater extent than the other diaphragms (P less than 0.01). The results show that the bell and diaphragm for a given stethoscope usually have different transmission characteristics, particularly at low frequencies. The Littmann Classic II is an exception. The Hewlett-Packard and Tycos Harvey stethoscopes showed the greatest differences in low frequency response between the bell and the diaphragm. While the differences found in sound transmission between stethoscopes were in most cases small, the Littmann Cardiology II, bell and diaphragm, appears to possess the best overall performance by this study design.

摘要

本研究使用声频发生器和有源人工耳评估了听诊器的声学性能。对六种目前市面上流行的听诊器在其涉及钟型听头、膜型听头等等的不同模式下进行了比较:Littmann Classic II、Littmann Cardiology II、Littmann Master Cardiology、惠普Rappaport-Sprague、泰科思Harvey三头听诊器以及艾伦医疗5A系列RPS双耳听诊器。测量了37.5至1000赫兹范围内的传递函数,这一范围涵盖了几乎所有的心音和肺音。在大多数情况下,低频范围(37.5至112.5赫兹)的声音通过钟型听头被放大,通过膜型听头被衰减;然而,并无显著差异。钟型听头和膜型听头在高频范围内均会衰减声音传播,且这种衰减随频率增加。泰科思Harvey三头听诊器的带肋膜型听头比其他膜型听头衰减声音传播的程度要显著更大(P小于0.01)。结果表明,对于给定的听诊器,其钟型听头和膜型听头通常具有不同的传播特性,尤其是在低频时。Littmann Classic II是个例外。惠普和泰科思Harvey听诊器在钟型听头和膜型听头的低频响应方面表现出最大差异。虽然在大多数情况下,不同听诊器之间声音传播的差异较小,但按照本研究设计,Littmann Cardiology II的钟型听头和膜型听头似乎总体性能最佳。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验