Nowak Lukasz J, Nowak Karolina M
Department of Intelligent Technologies, Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawinskiego 5B, 02-106 Warsaw, Poland.
Department of Endocrinology, Centre of Postgraduate Medical Education, Bielanski Hospital, Ceglowska 80, 01-809 Warsaw, Poland.
J Acoust Soc Am. 2017 Mar;141(3):1940. doi: 10.1121/1.4978524.
The present study introduces a detailed methodology which can be applied for objective evaluation and comparison of the acoustic parameters of medical stethoscopes using auscultation sounds as test signals. The described approach allows taking into account the acoustic coupling between the body of an auscultated patient and the chest piece of a stethoscope. Information obtained from additional, synchronized electrocardiography measurements is used to extract short, specific fragments of recordings, defined as acoustic events. Analysis of the spectral characteristics of many acoustic events allows us to compare the acoustic properties of various stethoscopes and to estimate the measurement uncertainty. The exemplary results of the comparative evaluation of acoustic properties of bell and diaphragm-type chest pieces of a single stethoscope are presented. The results show that the frequency characteristics of the signals obtained using both examined chest pieces under the conditions of the performed examinations are very similar.
本研究介绍了一种详细的方法,该方法可用于以听诊声音作为测试信号,对医用听诊器的声学参数进行客观评估和比较。所描述的方法能够考虑被听诊患者身体与听诊器胸件之间的声学耦合。从额外的同步心电图测量中获得的信息用于提取记录中的短特定片段,定义为声学事件。对许多声学事件的频谱特征进行分析,使我们能够比较各种听诊器的声学特性,并估计测量不确定度。给出了对单个听诊器的钟型和膜型胸件声学特性进行比较评估的示例结果。结果表明,在所进行的检查条件下,使用两种被检查胸件获得的信号的频率特性非常相似。