Roy Kajari, Kundra Pankaj, Ravishankar M
Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry, India.
Anesth Analg. 2005 Jul;101(1):294-5, table of contents. doi: 10.1213/01.ANE.0000156220.26900.B8.
Airway obstruction during general anesthesia is fairly common. Foreign body causing obstruction of the laryngeal mask airway is uncommon but can confuse the anesthesiologist trying to troubleshoot the cause of inability to ventilate. We present a case of complete airway obstruction with a nematode caught in the vertical bars of the laryngeal mask airway after its insertion.
全身麻醉期间气道梗阻相当常见。导致喉罩气道梗阻的异物并不常见,但可能会让试图排查通气障碍原因的麻醉医生感到困惑。我们报告一例在插入喉罩气道后,有一条线虫卡在喉罩气道垂直杆处导致完全气道梗阻的病例。