Suppr超能文献

超越通量:总角膜氧消耗作为隐形眼镜佩戴期间角膜氧合的指标。

Beyond flux: total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear.

作者信息

Brennan Noel A

机构信息

Brennan Consultants, Auburn Village, Australia.

出版信息

Optom Vis Sci. 2005 Jun;82(6):467-72. doi: 10.1097/01.opx.0000168560.10861.ae.

Abstract

PURPOSE

The purpose of this study is to compute total corneal oxygen consumption during contact lens wear and consider the concept as an index for describing corneal oxygenation during contact lens wear as opposed to flux, partial pressure, or Dk/t.

METHOD

Estimates of total corneal oxygen consumption were generated using a previously described eight-layer model based on oxygen diffusion equations and using contemporary estimates of tear and corneal layer thicknesses. Relative consumption, expressed as %Q (percentage of normal consumption without contact lens wear), was also calculated for daily wear and continuous wear modes, thereby providing an index of the chronic hypoxic effect of contact lens wear.

RESULTS

Corneal oxygen consumption is calculated to converge to the same value of 44.8 nL/cm/sec above a Dk/t of approximately 20 and 300 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) for the open and closed eye scenarios, respectively. Lenses with Dk/t values of 15 and 50 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) allow about 96% of normal long-term total oxygen consumption without a contact lens in place for daily wear and continuous wear, respectively. CONCLUSION.: Total corneal oxygen consumption is based on physical parameters, represents a direct index of corneal oxygen metabolism and thus cellular energy (ATP) production, allows direct comparison between two lenses or a lens and nonlens-wearing state, and eliminates the ambiguity of other measures, thereby providing an attractive means of describing corneal oxygenation.

摘要

目的

本研究的目的是计算佩戴隐形眼镜期间角膜的总氧消耗,并将这一概念作为描述隐形眼镜佩戴期间角膜氧合的指标,以区别于通量、分压或Dk/t。

方法

使用基于氧扩散方程的先前描述的八层模型,并采用当代对泪液和角膜层厚度的估计值,来生成角膜总氧消耗的估计值。还计算了日戴和连续佩戴模式下的相对消耗量,以%Q(无隐形眼镜佩戴时正常消耗量的百分比)表示,从而提供隐形眼镜佩戴慢性缺氧效应的指标。

结果

计算得出,在睁眼和闭眼情况下,当Dk/t分别约为20和300×10⁻⁹(厘米/秒)(毫升O₂/毫升/毫米汞柱)时,角膜氧消耗收敛到相同的值44.8纳升/厘米/秒。对于日戴和连续佩戴,Dk/t值分别为15和50×10⁻⁹(厘米/秒)(毫升O₂/毫升/毫米汞柱)的镜片,在不佩戴隐形眼镜的情况下,分别允许约96%的正常长期总氧消耗。结论:角膜总氧消耗基于物理参数,代表角膜氧代谢以及由此产生的细胞能量(ATP)的直接指标,允许在两片镜片之间或镜片与不佩戴镜片状态之间进行直接比较,并消除了其他测量方法的模糊性,从而提供了一种有吸引力的描述角膜氧合的方法。