Jun Beom-Cho, Kim Hyung-Tae, Kim Hyun-Soo, Cho Seung-Ho
Department of Otolaryngology-Head and Neck Surgery, School of Medicine, The Catholic University of Korea, Seoul, South Korea.
Acta Otolaryngol. 2005 Jul;125(7):774-8. doi: 10.1080/00016480510028546.
Functional 3D laryngeal CT (F3DLxCT) is an informative tool for visualizing the active changes in length, tension and mass of the vocal folds for pitch control. Furthermore, volume defects and level differences of paralyzed vocal folds are easily detectable with this new technique.
To evaluate the clinical feasibility of F3DLxCT images, which can provide clear coronal images of the vocal fold in each anteroposterior direction during phonation and in the resting state.
FLxCT images were reconstructed to three dimensions to visualize laryngeal motion. FLxCT was performed in four normal controls and in four patients with unilateral vocal fold paralysis in the resting state and during phonation with three vowel sounds of different pitch. 3D images were reconstructed with segmentation and a surface-rendering algorithm on a PC, using the DICOM file of axial images.
The dynamic vocal fold 3D image during phonation could visualize that the thickness and volume were decreased in relatively to the pitch increase. Typical subglottic shoulder-like image formation and ventricular widening were noted with the high-pitch tone.
功能性三维喉部CT(F3DLxCT)是一种有助于观察声带长度、张力和质量在音高控制过程中动态变化的信息工具。此外,利用这项新技术能够轻松检测出麻痹声带的体积缺陷和水平差异。
评估F3DLxCT图像的临床可行性,该技术能够在发声和静息状态下提供声带在各个前后方向上的清晰冠状面图像。
将FLxCT图像重建为三维图像以观察喉部运动。对4名正常对照者和4名单侧声带麻痹患者在静息状态下以及用三种不同音高的元音发声时进行FLxCT检查。使用轴向图像的DICOM文件,在个人电脑上通过分割和表面渲染算法重建三维图像。
发声时的动态声带三维图像能够显示出随着音高升高,声带厚度和体积减小。高音调时可观察到典型的声门下肩样图像形成和室带增宽。