A liquid chromatography method using volatile ion-pairing reagents and tandem mass spectrometry was developed to obviate observed matrix effect for ionizable polar compounds. The present study investigated the addition of volatile ion-pair reagents to the reconstitution solution instead of the mobile phase to enhance the efficiency of chromatographic separation and minimize the sensitivity loss due to the formation of ion-pairs. The volatile ion-pair reagents used were perfluorinated carboxylic acids with n-alkyl chains: heptafluorobutanoic acid (HFBA), nonafluoropentanoic acid (NFPA), tridecafluoroheptanoic acid (TDFHA) and pentadecafluorooctanoic acid (PDFOA). The model analytes evaluated were N-methylnicotinamide (MNA) chloride, N-methyl 2-pyridone 5-carboxamide (2PY) and phenylephrine. The effects of alkyl chain length and the concentrations of the ion-pair reagents on the retention of analytes were studied, as well as the effect of pH on the retention of phenylephrine. The volatile ion-pair reagents in the reconstitution solution showed significant effect on the retention of the ionizable polar compounds, and the sensitivity of detection was improved for plasma samples through decreasing the matrix effect. This methodology was successfully applied to establish a quantitative assay for the polar drug substance methadone in human plasma with a concentration range from 0.1 to 50 ng/mL. Ion-pair reagents not only shifted the retention time but also reduced the carry-over peak for methadone.

摘要

开发了一种使用挥发性离子对试剂和串联质谱的液相色谱方法,以消除可电离极性化合物中观察到的基质效应。本研究考察了在重构溶液而非流动相中添加挥发性离子对试剂,以提高色谱分离效率,并将因离子对形成导致的灵敏度损失降至最低。所使用的挥发性离子对试剂为带有正烷基链的全氟羧酸:七氟丁酸(HFBA)、九氟戊酸(NFPA)、十三氟庚酸(TDFHA)和十五氟辛酸(PDFOA)。评估的模型分析物为氯化N-甲基烟酰胺(MNA)、N-甲基-2-吡啶酮-5-甲酰胺(2PY)和去氧肾上腺素。研究了烷基链长度和离子对试剂浓度对分析物保留的影响,以及pH对去氧肾上腺素保留的影响。重构溶液中的挥发性离子对试剂对可电离极性化合物的保留有显著影响,通过降低基质效应提高了血浆样品的检测灵敏度。该方法成功应用于建立人血浆中极性药物美沙酮的定量测定方法,浓度范围为0.1至50 ng/mL。离子对试剂不仅改变了美沙酮的保留时间,还减少了其残留峰。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验