Suppr超能文献

一种采用胶束电动毛细管色谱法测定生发制剂中米诺地尔的方法。

A method for the determination of minoxidil in hair-regrowth formulations by micellar electrokinetic capillary chromatography.

作者信息

Gibson Gavin, Ramstad Tore, Mills Kent A, Dunn Michael J

机构信息

Department of Chemistry, Western Michigan University, Kalamazoo, MI 49008, USA.

出版信息

Farmaco. 2005 Oct;60(10):847-53. doi: 10.1016/j.farmac.2005.06.013. Epub 2005 Jul 25.

Abstract

A method based on micellar electrokinetic capillary chromatography (MEKC) was developed for determination of minoxidil in Rogaine and competing products. The original intent of the work was to offer an orthogonal means to HPLC for testing illicit imitations of Rogaine. However, because the patent has since expired, we offer the procedure as a confirmatory measure to HPLC for assay of generic minoxidil products. The MEKC procedure complements an earlier method based on free solution capillary electrophoresis (FSCE), designed to the same end. Validation was carried out on both a Dionex CES-1, which utilizes gravity injection, and a PE-ABI 270HT, which employs vacuum injection. The procedure was validated for both active pharmaceutical ingredient and for minoxidil solutions. The run buffer is pH 7.0, 20 mM sodium phosphate, 20 mM sodium dodecyl sulfate, with 10% isopropanol; the internal standard is dl-tryptophan. The method bears the attributes of simplicity, ease of use, and short analysis time (12 min). It is selective with respect to known process and degradation impurities. High efficiency was achieved on the CES-1, with a plate count exceeding 200,000 for minoxidil at an elution time of 9 min. Although slight differences in performance were noted across the two instruments, results on both were in conformance with modern day validation expectations. Comparison of MEKC with HPLC resulted in slightly higher values for the former, but all results met registration specifications and internal targets.

摘要

开发了一种基于胶束电动毛细管色谱法(MEKC)的方法,用于测定落健及其竞争产品中的米诺地尔。这项工作的初衷是提供一种与高效液相色谱法(HPLC)正交的方法,用于检测落健的非法仿冒品。然而,由于该专利现已过期,我们提供此方法作为HPLC测定米诺地尔仿制药产品的确认方法。MEKC方法补充了一种早期基于自由溶液毛细管电泳(FSCE)的方法,两者目的相同。在采用重力进样的戴安CES - 1仪器和采用真空进样的PE - ABI 270HT仪器上进行了方法验证。该方法针对活性药物成分和米诺地尔溶液均进行了验证。运行缓冲液为pH 7.0的20 mM磷酸钠、20 mM十二烷基硫酸钠以及10%异丙醇;内标为dl - 色氨酸。该方法具有操作简单、易于使用且分析时间短(12分钟)的特点。它对已知的工艺杂质和降解杂质具有选择性。在CES - 1仪器上实现了高效,米诺地尔在9分钟洗脱时间时的塔板数超过200,000。尽管两台仪器的性能存在细微差异,但两者的结果均符合现代验证要求。MEKC与HPLC的比较结果显示,前者的值略高,但所有结果均符合注册规格和内部目标。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验