Fabián J, Vojacek J, Grospic A, Prerovský I, Belán A, Hejhal L
Jpn Heart J. 1979 Nov;20(6):823-30. doi: 10.1536/ihj.20.823.
Using ultrasound method, aortocoronary bypass patency was determined by means of bidirectional Doppler's flowmeter. In 8 (3%) of 302 subjects without aortocoronary bypass was recorded diastolic signal which might distort the results of postoperative evaluation of graft patency. Two-hundred and ninety-seven patients with 330 aortocoronary bypasses were studied at the mean time of 8 months after operation. The graft patency was 84.5%. Comparison of 89 ultrasound findings with angiographic results established considerable specificity (90%) and sufficient sensitivity (77%). Reproducibility of this method was also good. The method is inexpensive and not time consuming. The advantages are also its safety and convenience for the patient. In the present level of development it can be used mainly as screening test at long-term follow-up of aortocoronary graft patency.
采用超声法,通过双向多普勒流量计测定主动脉冠状动脉搭桥术的通畅情况。在302例未行主动脉冠状动脉搭桥术的受试者中,有8例(3%)记录到舒张期信号,这可能会干扰移植血管通畅情况的术后评估结果。同时对297例接受了330次主动脉冠状动脉搭桥术的患者进行了研究,研究时间为术后平均8个月。移植血管通畅率为84.5%。将89例超声检查结果与血管造影结果进行比较,结果显示该方法具有较高的特异性(90%)和足够的敏感性(77%)。该方法的可重复性也很好。该方法成本低廉且不耗时。其优点还包括对患者安全方便。在目前的发展水平下,它主要可作为主动脉冠状动脉移植血管通畅情况长期随访的筛查试验。