Suppr超能文献

台湾两座城市固体废弃物焚化炉的气相/颗粒相中多氯二苯并二恶英/多氯二苯并呋喃同系物分布特征及排放情况

Characteristics of PCDD/F congener distributions in gas/particulate phases and emissions from two municipal solid waste incinerators in Taiwan.

作者信息

Chi Kai Hsien, Chang Moo Been, Chang-Chien Guo Ping, Lin Chieh

机构信息

Graduate Institute of Environmental Engineering, National Central University, Chungli 320, Taiwan.

出版信息

Sci Total Environ. 2005 Jul 15;347(1-3):148-62. doi: 10.1016/j.scitotenv.2004.12.032.

Abstract

Partitioning of PCDD/F (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuran) congeners between gaseous and particulate phases and removal efficiencies of the existing air pollution control devices (APCDs) for PCDD/Fs at two large-scale municipal waste incinerators (MWIs) in Taiwan are evaluated via stack sampling and analysis. Two MWIs investigated are equipped with activated carbon injection (ACI) and selective catalytic reduction system (SCR) as major PCDD/F control devices, respectively. The average PCDD/F concentrations of stack gases are 2.35 and 1.49 ng/N m(3), and the international toxic equivalent quantity (TEQ) are 0.17 and 0.043 ng TEQ/N m(3) in MWI-A and MWI-B, respectively. The average removal efficiency of PCDD/Fs achieved with ACI+BF (bag filters) reaches 95% (MWI-A) while that achieved with the WS (wet scrubber)+SCR system reaches 99% (MWI-B). The results obtained on gas/particulate partitioning in flue gases indicate that particulate-phase PCDD/Fs accounted for 27.7% and 24.7% of the total PCDD/F concentrations at the outlets of cyclone (CY) and electrostatic precipitator (EP) for MWI-A and MWI-B, respectively. But the gas/particulate partitioning in flue gas after PCDD/Fs control devices is quite different in two MWIs. This study also indicates that total 2,3,7,8-substituted PCDD/F discharges are 142.3 microg TEQ/ton waste for MWI-A and 98.6 microg TEQ/ton waste for MWI-B, respectively.

摘要

通过烟囱采样和分析,评估了台湾两座大型城市垃圾焚烧厂(MWIs)中多氯二苯并对二噁英和多氯二苯并呋喃(PCDD/F)同系物在气相和颗粒相之间的分配情况,以及现有空气污染控制设备(APCDs)对PCDD/Fs的去除效率。所研究的两座MWIs分别配备了活性炭喷射(ACI)和选择性催化还原系统(SCR)作为主要的PCDD/F控制设备。MWI-A和MWI-B烟囱气体中PCDD/F的平均浓度分别为2.35和1.49 ng/N m(3),国际毒性当量(TEQ)分别为0.17和0.043 ng TEQ/N m(3)。ACI+布袋除尘器(BF)实现的PCDD/Fs平均去除效率达到95%(MWI-A),而湿式洗涤器(WS)+SCR系统实现的去除效率达到99%(MWI-B)。烟道气中气体/颗粒分配的结果表明,对于MWI-A和MWI-B,旋风除尘器(CY)和静电除尘器(EP)出口处颗粒相PCDD/Fs分别占PCDD/F总浓度的27.7%和24.7%。但在两座MWIs中,PCDD/F控制设备之后烟道气中的气体/颗粒分配情况有很大不同。该研究还表明,MWI-A和MWI-B的2,3,7,8-取代PCDD/F总排放量分别为142.3微克TEQ/吨废物和98.6微克TEQ/吨废物。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验