Kobylianskiĭ A G, Kuznetsova T V, Soboleva G N, Bondarenko O N, Pogorelova O A, Titov V N, Masenko V P
Biomed Khim. 2003 Nov-Dec;49(6):597-603.
Two methods of measurement of nitrite and nitrate determination in human serum and plasma (a colorimetric method based on Griess reaction and a HPLC method) have been compared HPLC method revealed extremely low level of nitrites blood plasma, which was roughly the same (about 3 microM or less) in healthy donors, patients with diabetes and hypertension. The level of nitrates in the group of healthy donors (29.9 +/- 2.8 microM) is lower than in patients with diabetes (58.6 +/- 6.9 microM), and in patients with hypertension (35.4 +/- 2.5 microM). Comparison of data obtained by colorimetric and HPLC methods revealed close correlation (r = 0.77, p < 0.001). Methodical requirements for preparation of samples of serum and plasma of blood for analysis and correct intepretation of results are discussed in view of biochemical properties of nitric oxide molecule.