Suppr超能文献

人异体半月板移植的体内尺寸和运动特征:负重条件下的磁共振成像评估

Human meniscus allografts' in vivo size and motion characteristics: magnetic resonance imaging assessment under weightbearing conditions.

作者信息

Rankin Marc, Noyes Frank R, Barber-Westin Sue D, Hushek Stephen G, Seow Albert

机构信息

Rankin Orthopaedics and Sports Medicine Center, Washington, District of Columbia, USA.

出版信息

Am J Sports Med. 2006 Jan;34(1):98-107. doi: 10.1177/0363546505278706. Epub 2005 Oct 11.

Abstract

BACKGROUND

Although many reports have described clinical outcome of meniscus transplants, their size and motion patterns are not well understood. This study assessed postoperative in vivo size and motion patterns of meniscus transplants under full weightbearing conditions.

HYPOTHESIS

The human meniscus transplant has size and motion characteristics similar to the native menisci.

STUDY DESIGN

Case series; Level of evidence, 4.

METHODS

Eight meniscus transplants in 7 knees were studied 15 to 34 months postoperatively. The knees were scanned in an open magnetic resonance imaging 0.5-T superconducting magnet while standing. Single slice sagittal and coronal images were obtained at 0 degrees , 30 degrees , 60 degrees , and 90 degrees of flexion in the operative and contralateral knees.

RESULTS

The mean height and width of the anterior and posterior horns of the transplants were similar to those of native menisci. The millimeters of coronal displacement of motion of the midbody were also similar between the transplants and the native menisci. The anterior horn of the native medial menisci moved a mean of 5 mm more (total anterior to posterior translation, P < .05) than did the transplants. The posterior horn of the native medial menisci, and both horns of the native lateral menisci, also tended to move more than the corresponding horns of the transplanted menisci, although this result could not be confirmed statistically, given the number of menisci studied.

CONCLUSION

Meniscus transplants had similar size and midbody motion characteristics as the native menisci. The horns of the meniscus transplants tended to show decreased motion compared with the native menisci. The operative techniques and subsequent healing of the graft bone and peripheral attachments provided a stable meniscus construct.

摘要

背景

尽管许多报告描述了半月板移植的临床结果,但其大小和运动模式尚未得到充分了解。本研究评估了在完全负重条件下半月板移植术后的体内大小和运动模式。

假设

人类半月板移植具有与天然半月板相似的大小和运动特征。

研究设计

病例系列;证据等级,4级。

方法

对7例膝关节中的8个半月板移植进行了术后15至34个月的研究。在站立状态下,使用0.5-T超导开放式磁共振成像仪对膝关节进行扫描。在手术侧和对侧膝关节,分别在0度、30度、60度和90度屈曲时获取单层矢状面和冠状面图像。

结果

移植半月板前后角的平均高度和宽度与天然半月板相似。移植半月板和天然半月板的体部在冠状面的运动位移毫米数也相似。天然内侧半月板前角的移动平均比移植半月板多5毫米(前后总位移,P <.05)。天然内侧半月板后角以及天然外侧半月板的两个角,与移植半月板的相应角相比,也倾向于移动更多,尽管鉴于所研究的半月板数量,这一结果无法得到统计学证实。

结论

半月板移植具有与天然半月板相似的大小和体部运动特征。与天然半月板相比,移植半月板的角部运动倾向于减少。手术技术以及移植物骨和周边附着点的后续愈合提供了一个稳定的半月板结构。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验