Suppr超能文献

血液透析动静脉内瘘的B-flow超声评估:与低脉冲重复频率及高脉冲重复频率彩色和能量多普勒超声的比较

B-flow sonographic evaluation of hemodialysis fistulas: a comparison with low- and high-pulse repetition frequency color and power Doppler sonography.

作者信息

Yücel Cem, Oktar Suna Ozhan, Erten Yasemin, Bursali Aykut, Ozdemir Hakan

机构信息

Department of Radiology, Gazi University School of Medicine, 06510 Besevler, Ankara, Turkey.

出版信息

J Ultrasound Med. 2005 Nov;24(11):1503-8; quiz 1509-10. doi: 10.7863/jum.2005.24.11.1503.

Abstract

OBJECTIVE

The purpose of this study was to determine the effectiveness of B-flow sonography in the evaluation of hemodialysis fistulas and to compare this new technique with color and power Doppler sonography.

METHODS

In this study, 32 randomly selected patients (mean age, 46 years; age range, 18-87 years) with normally functioning hemodialysis fistulas were evaluated with low- and high-pulse repetition frequency (PRF) color and power Doppler sonography (PRF values of 3 and 10 kHz) and B-flow sonography. All images were reviewed and graded independently by 2 observers for luminal filling with flow signals, visibility of the intimal layer, and overall image quality. The study was approved by the Institutional Review Board, and informed consent was obtained from all patients.

RESULTS

Statistical analysis with Friedman and Wilcoxon signed rank tests revealed that B-flow sonography was superior to other techniques for luminal filling and visibility of the intimal layer (P = .000). For overall image quality, B-flow sonography was also the best method according to the Friedman test (P = .000). However, the Wilcoxon test showed no significant difference between B-flow and high-PRF (10-kHz) color and power Doppler sonography (P = .131). The kappa scores reflected moderate to good interobserver agreement (kappa = 0.285-0.784).

CONCLUSIONS

B-flow sonography is a relatively new and superior imaging technique that provides direct visualization of the blood echoes and the morphologic characteristics of the surrounding vessel wall simultaneously. During the evaluation of hemodialysis shunts, the major advantage of this technique is its ability to avoid artifacts such as aliasing and overwriting.

摘要

目的

本研究旨在确定B-flow超声在评估血液透析动静脉内瘘方面的有效性,并将这项新技术与彩色和能量多普勒超声进行比较。

方法

在本研究中,对32例随机选取的血液透析动静脉内瘘功能正常的患者(平均年龄46岁;年龄范围18 - 87岁)进行了低脉冲重复频率(PRF)和高脉冲重复频率(PRF)的彩色及能量多普勒超声(PRF值分别为3kHz和10kHz)以及B-flow超声检查。所有图像由2名观察者独立进行评估,评估内容包括管腔内血流信号充盈情况、内膜层的可视性以及整体图像质量。本研究经机构审查委员会批准,并获得了所有患者的知情同意。

结果

采用Friedman检验和Wilcoxon符号秩检验进行统计分析,结果显示B-flow超声在管腔内血流信号充盈及内膜层可视性方面优于其他技术(P = 0.000)。对于整体图像质量,根据Friedman检验,B-flow超声也是最佳方法(P = 0.000)。然而,Wilcoxon检验显示B-flow超声与高PRF(10kHz)彩色及能量多普勒超声之间无显著差异(P = 0.131)。kappa评分反映了观察者间的一致性为中等至良好(kappa = 0.285 - 0.784)。

结论

B-flow超声是一种相对较新且更优的成像技术,它能同时直接显示血液回声以及周围血管壁的形态特征。在评估血液透析分流时,该技术的主要优势在于能够避免诸如混叠和信号重叠等伪像。