Abstract

OBJECTIVE

It has been reported that delayed scan of thallium-201 (201Tl) scintigraphy is useful for differentiating malignant tumors from benign lesions and for evaluating treatment response. However, physiological muscle uptake which usually increases in delayed scans, often makes it difficult to evaluate 201Tl uptake and its washout in bone and soft-tissue tumors. The purpose of this study was to evaluate whether the delayed scan is necessary and whether a dynamic scan is useful in the evaluation of bone and soft-tissue tumors.

METHODS

We studied 175 cases of bone and soft-tissue tumors (malignant 45, benign 130). Dynamic scans were acquired every 5 seconds for 10 minutes after 201Tl injection, and time activity curves (TACs) were generated by adaptive smoothing methods. Early and delayed scans were acquired at 10-15 minutes and 2 hours after injection. 201Tl images were visually interpreted and the radioactivity count ratio (T/N) of tumors to normal tissues and washout rate [WR = (early T/N - delayed T/N)/early T/N] were defined.

RESULTS

When there were no 201Tl uptake in dynamic (n = 67) and early scans (n = 68), no tumor uptake was also appreciated in delayed scans, and all but two cases of negative scans were benign. In 107 lesions, although there were significant differences in T/Ns between malignant and benign lesions both on early scans (2.84 +/- 1.45 vs. 2.05 +/- 1.13, p < 0.05) and delayed scans (2.17 +/- 1.03 vs. 1.58 +/- 0.64, p < 0.05), there was a substantial overlap. The T/Ns decreased in delayed scans (i.e., WR > 0) in 100 of 107 cases due to increase of surrounding muscle uptake, and there was no difference in WR between malignant tumors and benign lesions (0.21 +/- 0.14 vs. 0.19 +/- 0.14).

CONCLUSIONS

For evaluating bone and soft-tissue tumors, delayed scan had little clinical usefulness and it may be time consuming. Dynamic scan would be useful for demonstrating the differences between tumor blood flow and 201Tl uptake in tumors.

摘要

目的

据报道,铊 - 201(201Tl)闪烁扫描的延迟扫描有助于鉴别恶性肿瘤与良性病变,并评估治疗反应。然而,生理肌肉摄取通常在延迟扫描中增加,这常常使得难以评估201Tl在骨和软组织肿瘤中的摄取及其洗脱情况。本研究的目的是评估延迟扫描是否必要以及动态扫描在骨和软组织肿瘤评估中是否有用。

方法

我们研究了175例骨和软组织肿瘤(恶性45例,良性130例)。在注射201Tl后,每5秒进行一次动态扫描,持续10分钟,并通过自适应平滑方法生成时间 - 活性曲线(TAC)。在注射后10 - 15分钟和2小时进行早期和延迟扫描。对201Tl图像进行视觉解读,并定义肿瘤与正常组织的放射性计数比(T/N)和洗脱率[WR =(早期T/N - 延迟T/N)/早期T/N]。

结果

当动态扫描(n = 67)和早期扫描(n = 68)中无201Tl摄取时,延迟扫描中也未发现肿瘤摄取,除两例阴性扫描外,所有阴性扫描病例均为良性。在107个病变中,尽管在早期扫描(2.84±1.45对2.05±1.13,p < 0.05)和延迟扫描(2.17±1.03对1.58±0.64,p < 0.05)中恶性和良性病变之间的T/N存在显著差异,但仍有大量重叠。由于周围肌肉摄取增加,107例中的100例在延迟扫描中T/N降低(即WR > 0),恶性肿瘤与良性病变之间的WR无差异(0.21±0.14对0.19±0.14)。

结论

对于评估骨和软组织肿瘤,延迟扫描临床实用性不大且可能耗时。动态扫描有助于显示肿瘤血流与肿瘤中201Tl摄取之间的差异。