Suppr超能文献

Percutaneous saphenous vein graft interventions with and without distal filter wire protection.

作者信息

Hofmann Manfred, Störger Hans, Schwarz Franz, Schwarz Claus-Eberhard, Reinemer Harald, Ruef Johannes, Schöpf Josef, Haase Jürgen

机构信息

The Red Cross Hospital Cardiology Center, Frankfurt/Main, Germany.

出版信息

J Interv Cardiol. 2005 Dec;18(6):475-9. doi: 10.1111/j.1540-8183.2005.00088.x.

Abstract

BACKGROUND

Embolic protection during SVG interventions using distal balloon occlusion and aspiration has shown to reduce periprocedural complications compared to unprotected SVG interventions. A similar effect is expected from filter wires.

PATIENTS AND METHODS

A total of 174 SVG interventions carried out with (group A; n=87) or without distal filter wire protection (group B; n=87) were retrospectively matched for the location of distal graft anastomosis and analyzed for baseline and procedural characteristics, for TIMI flow grade before and after PCI, for the post-procedural CK elevation, and for major adverse cardiac events at 30 days and 6 months (primary end point). Location of distal graft anastomosis was the left anterior descending artery in 19.6%, the left diagonal branch in 6.9%, the left marginal branch in 17.2%, the left posterolateral branch in 24.2%, the mid-segment of the right coronary artery in 28.7%, and the posterior descending artery in 3.4%.

RESULTS

Baseline clinical demographics showed no relevant differences between both the groups. Mean age of vein grafts was 11.7+/- 4.3 years in group A versus 10.6+/- 4.9 years in group B (P=0.15). The number of stents per lesion was 1.4+/- 0.8 in group A versus 1.0+/- 0.8 in group B (P<0.01). The total length of stents was 32.2+/- 16.2 mm in group A versus 20.9+/-12.1 mm in group B (P<0.01). TIMI flow grade pre was 2.5+/-0.8 in group A versus 2.7+/- 0.6 in group B (P<0.05). TIMI flow grade post was 2.9+/- 0.3 versus 2.9+/- 0.2. Improvement of TIMI flow grade after SVG intervention was 0.4+/- 0.7 in group A versus 0.2+/- 0.6 in group B (P<0.05). Post-procedural CK-MB elevations were observed in 17 patients of group A versus 14 patients of group B (P=0.18). At 30 days, there were no myocardial infarctions (MIs) and no deaths in either group. One patient of group A had to be reoperated and four patients of group A underwent repeat PCI (4.6%) versus one patient of group B (1.2%). At 6 months, there were again no MIs and no deaths in either group. Target lesion revascularization rate was 17.3% in group A versus 11.5% in group B (P <0.02).

CONCLUSION

When distal filter wire protection is used in high risk SVG lesions, the clinical outcome of percutaneous interventions may be equal to low risk SVG lesions without filter wire protection.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验