Suppr超能文献

继发孔型房间隔缺损手术闭合与使用Amplatzer封堵器闭合后儿童心功能的比较。

Comparison of cardiac function in children after surgical and Amplatzer occluder closure of secundum atrial septal defects.

作者信息

Pawelec-Wojtalik Małgorztata, Wojtalik Michal, Mrowczynski Wojciech, Surmacz Rafał, Quereshi Shakeel Ahmed

机构信息

Department of Paediatric Radiology, Poznań University of Medical Sciences, Poland.

出版信息

Eur J Cardiothorac Surg. 2006 Jan;29(1):89-92. doi: 10.1016/j.ejcts.2005.10.017. Epub 2005 Dec 6.

Abstract

OBJECTIVE

The aim of the retrospective study was to examine the changes in the left and right ventricular size as well as the systolic and diastolic function of the left ventricle after surgical and transcatheter treatment of atrial septal defects with Amplatzer atrial septal defect occluder (ASDO).

METHODS

Two groups of patients were examined using transthoracic cross-sectional echocardiography before and after the treatment of atrial septal defect: Group A--Amplatzer ASD occluder--38 children and Group S treated surgically--20 children. The following parameters were assessed: left and right ventricular end-diastolic diameter indexes, ejection fraction, mitral E wave to A wave velocity ratio, deceleration time (DCT), isovolumetric relaxation time (IVRT) and heart rate.

RESULTS

There was a significant decrease in right ventricular and an increase in left ventricular size in both groups during the follow-up observation. The long-term ECHO examination revealed smaller right ventricle (RV) (Group A: RVEDI=1.00+/-0.20 vs Group S RVEDI: 1.18+/-0.20 (p=0.001)) and bigger left ventricle (Group A: LVEDI=1.04+/-0.08 vs Group S: LVEDI=0.99+/-0.07 (p=0.022)) in Group A in comparison to Group S. Children undergoing operation had significantly shorter IVRT (Group A: IVRT=50.00+/- 9.65 vs Group S: IVRT=42.5+/- 8.95 (p=0.02)) than patients after ASDO device application.

CONCLUSIONS

(1) During the follow-up period, the diastolic function of the left ventricle is better in children with device closure of ASD compared with those patients treated surgically. (2) Postoperative changes of the left and right ventricular size indexes are more favourable in patients after the device closure of ASD compared with children undergoing the surgical procedure.

摘要

目的

本回顾性研究旨在探讨使用Amplatzer房间隔缺损封堵器(ASDO)对房间隔缺损进行手术治疗和经导管治疗后左、右心室大小以及左心室收缩和舒张功能的变化。

方法

在房间隔缺损治疗前后,使用经胸横断面超声心动图对两组患者进行检查:A组——使用Amplatzer ASD封堵器——38名儿童,S组——接受手术治疗——20名儿童。评估以下参数:左、右心室舒张末期直径指数、射血分数、二尖瓣E波与A波速度比、减速时间(DCT)、等容舒张时间(IVRT)和心率。

结果

在随访观察期间,两组患者的右心室均显著减小,左心室增大。长期超声心动图检查显示,与S组相比,A组右心室更小(A组:RVEDI = 1.00±0.20,S组RVEDI:1.18±0.20(p = 0.001)),左心室更大(A组:LVEDI = 1.04±0.08,S组:LVEDI = 0.99±0.07(p = 0.022))。接受手术的儿童的IVRT明显短于应用ASDO装置后的患者(A组:IVRT = 50.00±9.65,S组:IVRT = 42.5±8.95(p = 0.02))。

结论

(1)在随访期间,与接受手术治疗的患者相比,使用装置封堵ASD的儿童左心室舒张功能更好。(2)与接受手术的儿童相比,使用装置封堵ASD的患者术后左、右心室大小指数的变化更有利。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验