Sousa-Neto M D, Silva Coelho F I, Marchesan M A, Alfredo E, Silva-Sousa Y T C
Faculty of Dentistry, University of Ribeirão Preto, Ribeirão Preto, SP, Brazil.
Int Endod J. 2005 Dec;38(12):866-70. doi: 10.1111/j.1365-2591.2005.01027.x.
To evaluate the adhesion of an epoxy-based sealer to human dentine submitted to irradiation with Er : YAG or Nd : YAG laser at various parameters.
Ninety maxillary canine teeth were sectioned transversely at the cemento-enamel junction and at the root tip to leave an 8-mm-long cylinder. The tooth specimen was centred in a metallic ring (16 mm diameter and 8 mm height) and embedded in acrylic resin. The root canals were prepared using a low-speed handpiece and a conical diamond bur, which was attached to a paralleling device. This bur was lowered to a depth previously determined by a silicone stop. Specimens were divided into nine groups: group I, dentine was treated with 2 mL of 17% EDTAC for 5 min. Groups II-V were irradiated with Er : YAG laser at the following parameters: group II - 8 Hz and 200 mJ input (120 mJ output); group III - 8 Hz and 400 mJ input (240 mJ output); group IV - 16 Hz and 200 mJ input (120 mJ output); group V - 16 Hz and 400 mJ input (240 mJ output). Groups VI-IX were irradiated with Nd : YAG laser at the following parameters: group VI - 10 Hz and 1 W input (0.4 W output); group VII - 10 Hz and 2 W input (0.8 W output); group VIII - 15 Hz and 1 W input (0.4 W output); group IX - 15 Hz and 2 W input (0.8 W output). The root canals were filled with an epoxy-based root canal sealer and submitted to a push-out test.
Statistical analysis showed significant differences (P < 0.01) between Er : YAG and Nd : YAG laser treatments at the higher frequencies compared with 17% EDTAC. Greater adhesion values were obtained for groups IV and V (Er : YAG laser) and groups VIII and IX (Nd : YAG laser), which were statistically different from groups II and III (Er : YAG laser) and groups VI and VII (Nd : YAG laser). Treatment with only 17% EDTAC had the lowest adhesion values.
An increase in frequency, independent of power settings, of the lasers used in this study increased adhesion of an epoxy-based root canal sealer.
评估在不同参数下,基于环氧树脂的封闭剂与经铒:钇铝石榴石(Er:YAG)或钕:钇铝石榴石(Nd:YAG)激光照射的人牙本质之间的黏附力。
90颗上颌尖牙在牙骨质-釉质界和根尖处横向切割,留下8毫米长的圆柱体。将牙齿标本置于金属环(直径16毫米,高8毫米)中心,并用丙烯酸树脂包埋。使用低速手机和连接在平行装置上的锥形金刚砂车针预备根管。该车针下降至先前由硅橡胶阻挡器确定的深度。标本分为9组:I组,牙本质用2毫升17%乙二胺四乙酸(EDTAC)处理5分钟。II-V组用Er:YAG激光以以下参数照射:II组-8赫兹,输入200毫焦(输出120毫焦);III组-8赫兹,输入400毫焦(输出240毫焦);IV组-16赫兹,输入200毫焦(输出120毫焦);V组-16赫兹,输入400毫焦(输出240毫焦)。VI-IX组用Nd:YAG激光以以下参数照射:VI组-10赫兹,输入1瓦(输出0.4瓦);VII组-10赫兹,输入2瓦(输出0.8瓦);VIII组-15赫兹,输入1瓦(输出0.4瓦);IX组-15赫兹,输入2瓦(输出0.8瓦)。用基于环氧树脂的根管封闭剂充填根管,并进行推出试验。
统计分析显示,与17%EDTAC相比,在较高频率下,Er:YAG和Nd:YAG激光治疗之间存在显著差异(P<0.01)。IV组和V组(Er:YAG激光)以及VIII组和IX组(Nd:YAG激光)获得了更高的黏附值,与II组和III组(Er:YAG激光)以及VI组和VII组(Nd:YAG激光)在统计学上有差异。仅用17%EDTAC处理的黏附值最低。
在本研究中使用的激光,频率增加(与功率设置无关)会增加基于环氧树脂的根管封闭剂的黏附力。