Suppr超能文献

经枯草芽孢杆菌挑战的选定呼吸防护设备的功效。

Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger.

机构信息

Life Sciences Division (MT-L), U.S. Army Dugway Proving Ground, Dugway, Utah 84022.

出版信息

Appl Environ Microbiol. 1994 Jun;60(6):2184-6. doi: 10.1128/aem.60.6.2184-2186.1994.

Abstract

The efficacy of powered air-purifying respirators, surgical masks, dust/mist respirators, and high-efficiency respirators were tested with a biological aerosol under simulated breathing conditions. Protective ability ranged from 67 to 99.95%. The majority of penetration in negative-pressure respirators occurred at the face-mask interface rather than through the filter material.

摘要

动力空气净化呼吸器、外科口罩、防尘/雾口罩和高效呼吸器在模拟呼吸条件下用生物气溶胶进行了测试。防护能力范围为 67%至 99.95%。负压呼吸器中的大部分渗透发生在面罩接口处,而不是通过过滤材料。

相似文献

1
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger.
Appl Environ Microbiol. 1994 Jun;60(6):2184-6. doi: 10.1128/aem.60.6.2184-2186.1994.
2
Respiratory protection and the risk of Mycobacterium tuberculosis infection.
Am J Ind Med. 1995 Mar;27(3):317-33. doi: 10.1002/ajim.4700270302.
4
5
Filter penetration and breathing resistance evaluation of respirators and dust masks.
J Occup Environ Hyg. 2017 Feb;14(2):148-157. doi: 10.1080/15459624.2016.1237027.
6
Medical face masks offer self-protection against aerosols: An evaluation using a practical in vitro approach on a dummy head.
PLoS One. 2021 Mar 3;16(3):e0248099. doi: 10.1371/journal.pone.0248099. eCollection 2021.
8
Powered, air-purifying particulate respirator filter penetration by a DOP aerosol.
J Occup Environ Hyg. 2006 Nov;3(11):620-30. doi: 10.1080/15459620600953995.
9

引用本文的文献

1
Association between increased DNA mutational frequency and thermal inactivation of aerosolized spores exposed to dry heat.
Aerosol Sci Technol. 2011;45(3):376-381. doi: 10.1080/02786826.2010.538452. Epub 2011 Jan 3.
2
Application of ATP-based bioluminescence for bioaerosol quantification: effect of sampling method.
J Aerosol Sci. 2015 Dec 1;90:114-123. doi: 10.1016/j.jaerosci.2015.08.003.
3
Viable viral efficiency of N95 and P100 respirator filters at constant and cyclic flow.
J Occup Environ Hyg. 2013;10(10):564-72. doi: 10.1080/15459624.2013.818228.

本文引用的文献

1
Predicted values for clinical exercise testing.
Am Rev Respir Dis. 1984 Feb;129(2 Pt 2):S49-55. doi: 10.1164/arrd.1984.129.2P2.S49.
2
Respirator cartridge filter efficiency under cyclic-and steady-flow conditions.
Am Ind Hyg Assoc J. 1973 May;34(5):182-92. doi: 10.1080/0002889738506832.
3
Epidemiology of tuberculosis in the United States.
Epidemiol Rev. 1989;11:79-98. doi: 10.1093/oxfordjournals.epirev.a036046.
4
Drug-resistant tuberculosis.
Clin Chest Med. 1989 Sep;10(3):341-53.
5
Tuberculosis: commentary on a reemergent killer.
Science. 1992 Aug 21;257(5073):1055-64. doi: 10.1126/science.257.5073.1055.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验